Horizon Fitness 642E Operator's Manual

Horizon Fitness 642E Operator's Manual

Laboratory centrifuge

Advertisement

Replacement Parts:
Part No.
Description
7724037
Foot, rubber
7751068
Switch, lid safety
7786061
Rotor, six-place, horizontal
7735049
Motor, 1/30 H.P., 115 V.A.C. permanent split capacitor
7729006
Capacitor, 4uF, 250V A.C.
7717051
Electronic timing and locking board
7751043
Circuit Breaker
03-0-0003-0068
Front Panel Label
7760002
Power cord
7714101
Pawl, latch, lid
7714103
Knob, latch, lid
7724071
Hinge, friction
7732018
Seal, lid gasket
7713031
Red Tube Holder, for 17 mm x 100 mm tubes
7713033
Green Tube Holder, for 17 mm x 75 mm Tubes
02-002-1-0011
Lid Assembly
Available Accessories:
1" Tube cushion
0.25" Tube cushion
p/n 1525
p/n 9150
0.5 to 1 mL Tube Adapter
Shield caps
p/n 7713011
p/n 7713068
The Drucker Company warranties that this centrifuge is free from defects
in workmanship and parts for 2 years.
Made in the USA by
200 Shady Lane, Suite 170 • Philipsburg, PA 16866
Phone: 814-342-6205 or 814-692-7661 • Fax: 814-692-7662 • www.druckercompany.com
13 x 75 mm Insert
13 x 100 mm Insert
p/n 7713064
1.5 to 2 mL Tube Adapter
p/n 7713065
WARRANTY:
Programmable
Run Time is Factory
10
MINUTES
p/n 7713066
Operator's Manual
Rev. F
Preset to
See Page 5
Model 642E • Laboratory Centrifuge
P/N 03-0-0002-0039
Protected by U.S. patent # 6,811,531

Advertisement

loading

Summary of Contents for Horizon Fitness 642E

  • Page 1 2 years. Operator’s Manual Made in the USA by Protected by U.S. patent # 6,811,531 Model 642E • Laboratory Centrifuge Rev. F 200 Shady Lane, Suite 170 • Philipsburg, PA 16866 Phone: 814-342-6205 or 814-692-7661 • Fax: 814-692-7662 • www.druckercompany.com...
  • Page 2: Table Of Contents

    Features pg. 3 microorganisms. When Risk Group II ma- Lid Safety Switch: The Model 642E lid is secured to the top of the cabinet by Specifications pg. 3 terials are used, (as identified in the World a latching knob and pawl system.
  • Page 3: Features

    – The printed circuit board may be damaged. Have a technician test Specifications: and replace the circuit board if necessary. General Specifications for the Model 642E Centrifuge 4. Problem: The latch light does not come on when the lid is closed.
  • Page 4 Choose a setup location which meets the following criteria: A bench top clearance height of 20” is required in order to open the lid. Provide Adequate Ventilation: For cooling purposes, the Model 642E draws in The clearance envelope is the space around the centrifuge which is ambient air through the air intake cover on the top of the lid and exhausts required for safety.
  • Page 5 (Continued) 12. Push the ‘OPEN / STOP’ button. The ‘RUNNING’ indicator light should The Model 642E is capable of spinning test tubes up to 17 mm x 100 mm with go out and the motor should slow to a stop.
  • Page 6: Operation

    (Continued) BALANCED LOADS Your centrifuge must contain a balanced load in order to work properly. Press START one time for each minute of run time desired, from a minimum of Use the following rules when loading the rotor. 1 minute to a maximum of 30 minutes. The green START indicator light will flash Spinning balanced loads will extend the life of the machine and each time you press the START button.