HELP02
Adhesive bond (B-10): J-6082-612-A
1.
Perform the "4-2-2. Aperture Diameter Adjustment" before attaching the front ball lens block.
2.
Attach the front ball lens block, and perform the "4-4-2. Flange Back (f'F) Adjustment".
Note:
Attach the three screws fixing the front ball lens block as shown in the figure.
3.
After the flange back (f'F) adjustment is completed, tighten the six screws and apply the adhesive bond (B-10) to them as shown in
the figure.
Front Ball Lens Block
Apply the adhesive
bond (B-10) (6 areas)
Focus Operating Ring
HELP03
Anti-diffusion agent (A-20): J-6082-611-A
Apply the anti-diffusion agent (A-20) to the instruction part of the distance tube block.
Note:
When attaching the focusing ring, set the distance tube block to the infinity position.
Distance Tube Block
Apply the anti-diffusion agent (A-20)
(All circumference)
SAL50F14 (1.4/50) (50mm F1.4)
Screw
5 mm
Apply the anti-diffusion agent (A-20)
(All circumference)
Screws
Focus scale window
position
HELP