Function Tests

Do Not Operate Unless:
You learn and practice the principles of safe
machine operation contained in this operator's
manual.
1 Avoid hazardous situations.
2 Always perform a pre-operation
inspection.
3 Always perform function tests prior to
use.
Know and understand the function tests
before going on to the next section.
4 Inspect the work place.
5 Only use the machine as it was intended.
Fundamentals
The Function Tests are designed to discover any
malfunctions before the machine is put into
service. The operator must follow the step-by-step
instructions to test all machine functions.
A malfunctioning machine must never be used. If
malfunctions are discovered, the machine must be
tagged and removed from service. Repairs to the
machine may only be made by a qualified service
technician, according to the manufacturer's
specifications.
After repairs are completed, the operator must
perform a pre-operation inspection and function
tests again before putting the machine into service.
14
Genie Z-20/8N & Genie Z-20/8 & Genie Z-25/8
1 Select a test area that is firm, level and free of
obstruction.
2 Be sure both battery connectors are connected.
At the Ground Controls
3 Turn the key switch to ground control.
4 Pull out the red Emergency Stop button to
the on position.
Result: The beacon (if equipped) should flash.
Test Emergency Stop
5 Push in the red Emergency Stop button to the
off position.
Result: No ground or platform control functions
should operate.
6 Pull out the red Emergency Stop button to
the on position.
Test the Boom Functions
7 Do not hold the function enable switch to either
side. Attempt to activate each boom and
platform function toggle switch.
Result: No boom or platform functions should
operate.
8 Hold the function enable switch to either side
and activate each boom and platform function
toggle switch.
Result: All boom and platform functions should
operate through a full cycle. The descent alarm
(if equipped) should sound while the boom is
lowering.