For The Installer: Final Check List & Start Up - Scotsman MDT5N40A-1J Installation And User Manual

Ice maker-dispenser
Hide thumbs Also See for MDT5N40A-1J:
Table of Contents

Advertisement

MDT5N25 & MDT5N40 User Manual
FOR THE INSTALLER: Final Check List & Start Up
1. Is the icemaker-dispenser installed indoors, in a
location where the air and water temperatures are
controlled, and where they do not go beyond
design limitations?
2. Is there an electrical disconnect (switch or plug
as required) within sight of the installed machine?
Is the machine on a separate circuit? Has the
voltage been checked and compared to nameplate
requirements?
3. Have all of the plumbing connections been
made and checked for leaks?
4. Has the machine been leveled?
5. Is there a minimum of 6 inches of clearance at
the left and right sides of an air cooled machine?
6. Is there a minimum of 6 inches of clearance at
the top and back of the machine for service and
utility connections?
Wall mounted only: Is the machine properly
installed and secured to the wall?
7. Is there a water shut off valve installed near the
machine?
INITIAL START UP
Pre Start Inspection
1. Remove the two front panels.
2. Check that all shipping blocks have been
removed.
3. Remove any and all packing tape (check inside
the storage bin).
4. Inspect the interior of the machine for loose
screws or wires. Check that no refrigerant lines are
rubbing each other. Check that the fan blade on air
cooled models turns freely.
5. Check that the machine is installed correctly
according to the final check list.
Start Up
1. Go through the pre start inspection.
2. Open the water hand valve, observe that water
enters the water reservoir, fills the tube from the
reservoir to the evaporator and then shuts off.
Check for leaks.
3. Switch the master switch on. The electrical start
up sequence is automatic; there will be a short (15
second) delay before the machine starts.
4. On air cooled models, warm air will begin to flow
from the condenser. Water cooled models will
begin to discharge warm water (110
drain.
5. The unit should soon be making ice.
BACK VIEW OF COMPLETED INSTALLATION
PLUMBING?
MACHINE
6. There are no adjustments to make, so replace
the panels.
7. Check ice dispensing by holding a container in
front of the Touch Free ice sensor (just below the
ice delivery spout). Ice should flow from the spout
when a container is present, and stop dispensing
when the container is removed.
8. Switch off the icemaker-dispenser, remove the
top panel and the top of the ice storage bin.
Sanitize the interior of the ice storage bin by wiping
it with a mixture of 1 ounce of household bleach to
2 gallons of water, allow to air dry. Replace all
covers and panels. Switch the icemaker-dispenser
back on.
9. Give the owner/user the service manual, instruct
him/her in the operation and maintenance
requirements of the unit. Make sure they know who
to call for service.
o
F) down the
10. Fill out the Customer Evaluation and Warranty
Registration form, and mail it in to Scotsman.
November 2008
Page 8
STAND
ELECTRICAL?
LEVELED?

Advertisement

Table of Contents
loading

Table of Contents