D Setting The Scan Stop Timer; Open Scan; Group And Priority Scan - Icom IC-41PRO Advanced Manual

Hide thumbs Also See for IC-41PRO:
Table of Contents

Advertisement

4
SCAN
Scanning preparation (Continued)

D Setting the Scan Stop Timer

q Hold down [TOP] for 2 seconds to enter the Set
mode.
w Push [Side 1] or [Side 2] several times to select the
Scan Stop Timer function.
• "S-TIME" is displayed.
e Rotate [ROTARY SELECTOR] to select the scan stop
time.
5/10/15:
Scan pauses for 5, 10 or 15 seconds when a signal is
detected, then resumes.
P5:
Scan pauses until the signal disappears, and then
resumes after 5 seconds (Recommended setting).
r Hold down [TOP] for 2 seconds to set and exit the
Set mode.
Scan Stop Timer
P5 (default)

Open scan

An Open scan automatically searches for busy
channels and enables you to locate new stations for
communication or listening.
q Push
several times until Open scan is selected.
• "
" is displayed.
Displayed
w Push
to start the scan.
e When receiving a signal, the scan pauses and
resumes, according to the selected Scan Stop
Timer setting.
r Push
to cancel the scan.
10 second setting
Blinks
Scan start channel

Group and Priority scan

Group and Priority scans repeatedly searches for
a signal on the Priority channel while scanning the
tagged channels. This is useful when waiting for a call
on the Priority channel or several tagged channels.
Group and Priority scans are performed differently
while transmitting. Group scan searches on a Prior-
ity channel or on a busy channel, and Priority scan
searches only on the Priority channel.
q Push
until Group or Priority scan is selected.
• "
" is displayed when Group scan is selected, and
"
" is displayed when Priority scan is selected.
Displayed
Group scan is selected.
w If Priority scan is selected in step q, set the
Priority channel by holding down
after selecting the desired channel.
• To cancel the Priority channel setting, push [TOP] to
enter the Function mode, and then hold down
seconds.
e Push
to start the scan.
Group scan starts.
Priority scan starts.
*Priority channel is displayed instead of the scan start channel
if the Priority channel is set in step w.
r When receiving a signal, the scan pauses and then
resumes according to the Scan Stop Timer setting.
t Push
to cancel the scan.
9
Displayed
Priority scan is selected.
for 2 seconds
for 2
Appears
Blinks
Scan start channel*
Blinks
Priority channel*

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents