Design

2-3-4 Resolver Wiring

Use OMRON Resolver Cables which are designed to reduce noise.
Resolver Cables transfer signals that require a high degree of accuracy. Separate the
Resolver Cables from other cables as much as possible to prevent the accuracy being
affected by induction noise resulting from low signal voltage.
S Separate Resolver Cables as much as possible from control and drive wiring inside
the control panel.
S For external wiring, house the cables in a low-current duct and shield with grounded
conduction plates.
The Cam Positioner and Resolver can be separated by a maximum distance of 100 m.
H Resolver Wiring Method
3F88L-160/162 Cam Positioner
3F88L-160/162 Cam Positioner
3F88L-160/162 Cam Positioner
3F88L-CRjjjC Extension Cable
3F88L-CRjjjNA Cable
3F88L-CRjjjSA Cable
Chapter 2
3 m plug-in cable
3F88L-RS17/-RS17T Resolver
Connector type
3F88L-RS15 Resolver
35-cm Separate wire
plug-in cable
3F88L-RS15W Resolver