Omron 3F88L-160 User Manual page 186

Cam positioner
Hide thumbs Also See for 3F88L-160:
Table of Contents

Advertisement

Operation
Error
Error name
code
(Error
Power OFF
indica-
watchdog
tor not
error
lit)
5-6
Description
Cam
output
Power is not
F
turned ON;
RESET input
has been
turned ON;
software error
Probable
Possible solution
cause
Power has
Check that the
turned OFF.
voltage supplied to
the Cam Positioner
meets the
specifications (85 to
264 V AC) and
adjust if necessary.
RESET input
Adjust the RESET
has been
input sequence.
turned ON.
RESET input
Find the source of
has been
the noise and take
turned ON due
appropriate
to noise.
countermeasures.
Check and adjust the
wiring for control
input signals.
The Cam
Replace the Cam
Positioner is
Positioner.
malfunctioning
(system does
not recover
when power is
turned ON
again.)
Chapter 5
Error reset
method
Turn ON the
power again.
---

Hide quick links: