Sharp LC-50U35T Service Manual page 15

Lcd color television
Table of Contents

Advertisement

Point 6
[Adjustment value]
LEV60115
Based on Teaching set
MG6G****
After adjust luminance spec: Min 280cd/m2
MG6B****
[Reference value for adjustment]
MG6R****
Equipment : Luminance meter [Minolta CS-2000]
Point 5
LEV50040
MG5G****
MG5B****
(DYNAMIC MODE)
MG5R****
Point 4
Point 7
LEV40000
MG4G0000
Point 6
MG4B0000
Point 5
MG4R0000
Point 4
Point 3
Point 3
Point 2
LEV30000
Point 1
MG3G0000
Remarks
MG3B0000
MG3R0000
Point 2
LEV20000
MG2G0000
MG2B0000
MG2R0000
Point 1
LEV10000
MG1G0000
MG1B0000
MG1R0000
W/B adj. value data
input
MSET0003
Referenc
Level
e value
3664
x=0.2685
y=0.2670
x=0.2685
1840
y=0.2670
x=0.2685
640
y=0.2670
0
0
0
0
For inspection set condition
AV MODE : [DYNAMIC]
Monochrome : ON
Active Backlight : OFF
Aging time : Minimum 60 min.
5 – 7
LC50/58/65U35T
Adjustment
Inspection
Spec.
Spec.
±0.0010
±0.0020
±0.0015
±0.0030
±0.0045
±0.0090
NO USE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lc-65u35tLc-58u35t

Table of Contents