10.15.10. Removing the Up/down gear block
*You cannot replace the Up/down shaft or Up/down motor unless you disassemble the Up/down gear block.
*Proceed the procedures of 1-4 of 10.15.5. Removing the Width sensor.
1.
Remove the Massage mechanism block from the Rear frame.
2.
Unscrew ten Screws on the Massage mechanism block frame, Up/down driving block install plate, and Intensity driving
block install plate.
3.
Unscrew two Screws on the Up/down sensor install plate.
4.
Unscrew three Screws on the Up/down gear box and the Up/down driving block install plate.
5.
Unscrew four Screws on the Up/down gear box A/B.
6.
Unscrew two Screws on the Up/down gear box and the Up/down motor. (One of them is the Grounding terminal.)
10.15.11. Removing the Up/down shaft (Up/down shaft bolt)
*Work with the Massage mechanism block unloaded.
1.
Remove the Up/down shaft bolt on the Pinion B/C with the 13mm box driver and the Phillips screwdriver.
Caution in assembly
- The Up/down shaft bolt may be broken if tightened excessively.
To tighten it, use the Torque wrench with the torque, 35 to 45kgfcm (350-450Ncm).