3.17 SPARK GENERATOR REPLACEMENT

1.
Refer to Sections 3.2 & 3.3.
2.
Disconnect the leads from the spark generator.
3.
Remove spark generator by pulling forwards
to release the retaining clip, then push back to
release the second retaining clip.
4.
Fit the new spark generator and re-assemble in
reverse order ensuring that the the earth lead is
replaced.
5.
Check the operation of the boiler. Refer to
Sections 2.24 - 2.27.

3.18 GAS CONTROL VALVE REPLACEMENT

1.
Refer to Sections 3.2 & 3.3.
2.
Remove the gas inlet pipe. Refer to Section 3.4.
3.
Unplug the electrical connection.
4.
Disconnect the gas service cock, refer to Section
2.23.
5.
Remove the 2 securing screws in the underside of
the boiler casing and remove the valve.
6.
Remove brass injector from gas valve outlet and re-fit
into replacement valve.
7.
Replace in reverse order ensuring all seals are in
good condition and the assembly is gas sound.
8.
Check the operation of the boiler. Refer to Sections
2.24 - 2.27.

3.19 CONDENSATE TRAP REPLACEMENT

1.
Refer to Sections 3.2 & 3.3.
2. Remove the rubber condensate pipe from
the top of the trap.
3. Rotate the trap clockwise to disengage
the trap and lift clear of the outlet
connection.
4. Replace the trap and refit in reverse order
making sure the trap is engaged with the
outlet connection.
5. Refill the condensate trap.
6. Check the operation of the boiler. Refer to
Sections 2.24 - 2.27.
Installation and Servicing