Cabinet design and EMC Booksize
12.8 Connection systems
12.8.6.3
Removing the motor connector from prefabricated power cables
The motor connector of a pre-assembled motor cable might have to be removed if the cable
needs to be routed through narrow cable glands, for example.
Figure 12-31 Motor connector, crimped version
Removing the motor connector
1. First loosen the clamp.
2. Simultaneously press the tabs A and B on both sides of the connector using a
screwdriver.
3. Keep both tags pressed and lift the interlock mechanism e.g. using a screwdriver.
4. Remove the Insert and withdraw the motor cable out of the connector.
Figure 12-32 Removing the motor connector, crimped version
750
Booksize Power Units
Manual, (GH2), 04/2014, 6SL3097-4AC00-0BP6