Technical Data Table - Ariston 80 L Technical Manual

Heat pump water heater split
Hide thumbs Also See for 80 L:
Table of Contents

Advertisement

Description
INTERNAL UNIT
Rated tank capacity
Insulation thickness
Type of internal tank protection
Type of corrosion protection
Maximum operating pressure
Diameter of hydraulic connections
Diameter of gas connections
Minimum water hardness
Weight when empty
Heating element power
Protection rating
Min. temperature of room of installation
EXTERNAL UNIT
Heat rating (*)
Average electrical power consumption (*)
Max. electrical power consumption (*)
Refrigerant connection diameter
Weight when empty
Standard air flow rate
Sound power
Level of sound pressure at 5 m
Max. pressure of refrigerating circuit (low-
pressure side)
Max. pressure of refrigerating circuit (high-
pressure side)
Protection rating
Minimum air temperature (***)
Maximum air temperature (***)
Gas connection maximum length
Gas connection maximum drop
Quantity of R134a refrigerant fluid
PERFORMANCES
COP (*)
Heating time with heat pump (*)
Heating energy consumption (*)
Max. amount of hot water
in a single intake V40 (**)
Max. water temperature with heat pump
Max. water temperature with heating
element
QPr (over 24h)
POWER SOURCE
Voltage / max. power consumption (*)
Frequency
Max. current consumption
(*) values obtained with air temperature of 7°C, 87% relative humidity; input water temperature 15°C, setting temperature 55 °C, in
compliance with EN255-3 norm.
(**) Performance measured for input water temperature 15°C.
(***) outside of the heat pump's interval of operation, heating of the water is ensured by the heating element..
Average value obtained on a significant number of products.
Unit of
measurement
mm
MPa
m3/h
dB(A)
dB(A)
MPa
MPa
Unit of
measurement
h:min
kWh
Delivered at 55°C
Delivered at 62°C
kWh
V / W

TECHNICAL DATA TABLE

80 L
l
80
≈ 41
titanium impressed current anode + disposable magnesium anode
°F
kg
32
W
1200
IP24
°C
1
W
W
W
kg
°C
°C
m
m
g
80 L
2,9
2:45
1,20
l
95
l
113
°C
62 (55 factory default)
°C
75 (65 factory default)
0,46
Hz
A
6
100 L
103
≈ 41
enamelling
0,8
1/2 M
1/4" & 3/8" flare type
12 (with water softener, min 15°F)
35
1200
IP24
1
1500
510
750
1/4 & 3/8 flare type
27
1100
55
39
1.2
2.7
IP24
-5
42
6
3
700
100 L
2,9
3:26
1,53
130
152
62 (55 factory default)
75 (65 factory default)
0,50
220-240 single-phase / 1950
50
8,5
110 L
110
≈ 41
38
1200
IP24
1
110 L
2,9
3:42
1,64
144
169
62 (55 factory default)
75 (65 factory default)
0,50

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

100 l110 l

Table of Contents