SINAMICS G110 Performance Ratings
Feature
Mains operating voltage
and power ranges
Input frequency
Output frequency
Cos ϕ
Inverter efficiency
Overload capability
User Power Supplies
Inrush current
Control method
Pulse frequency
Fixed frequencies
Skip frequency
Setpoint resolution
Digital inputs
Analog input (Analog
Variant)
Digital output
Serial interface (USS
Variant)
Motor cable length
Electromagnetic
compatibility
Braking
Protection level
Temperature range
Storage temperature
Humidity
Operational altitudes
Protection features for
• under-voltage
• short circuits
Conformity with
standards
CE marking
Dimensions and weights
(without options)
A up to 370W
A 550 & 750W
A Flat Plate Version up to 370W
A Flat Plate Version 550 W & 750 W
B 1.1 kW & 1.5 kW
C 2.2 kW
C 3.0 kW
SINAMICS G110
Operating Instructions
6SL3298-0AA11-0BP0
Specification
200 V to 240 V (±10%) 1AC
47 to 63 Hz
0 Hz to 650 Hz
≥ 0.95
Below 750 W = 90% to 94%. On 750W units and higher ≥ 95%
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s; then 0.85 x rated
output current for 240 s, cycle time 300 s
24 V on pins 6 and 7 (50 mA unregulated supply): 10 V on pins 8 and 10 (5 mA)
less than rated input current
linear V/f; quadratic V/f; multipoint characteristic (programmable V/f)
8 kHz (standard); 2 kHz to 16 kHz (in 2 kHz steps)
3 programmable
1 programmable
0.01 Hz digital, 0.01 Hz serial, 10 bit analog (motor potentiometer 0.1 Hz)
3 programmable digital inputs, non-isolated; PNP, SIMATIC-compatible, low < 5V: high > 10 V:
maximum input voltage 30 V.
1 for setpoint (0 V to 10 V, scaleable or for use as 4th digital input)
1 isolated optocoupler output (24 Vdc, 50 mA resistive), NPN transistor type
RS-485, for operation with USS protocol
max. 25 m (shielded)
max. 50 m (unshielded)
All units available with internal EMC filter for Category C2 (restricted availability) – PDS installations
(specifies limits equivalent to EN55011, Class A). In addition all units with integral filters for screened
motor cables up to 5 m will meet the limits to EN55011 Class B.
Compound Braking (firmware 1.1 only), DC Braking
IP20
–10 °C to +40 °C (up to +50 °C with derating)
–40 °C to +70 °C
95 % (non-condensing)
up to 1000 m above sea level without derating
• over-voltage
• stall prevention
UL, cUL, CE, c-tick
Conformity with EC low voltage directive 73/23/EC
Frame size (FS)
SINAMICS G110 Specifications
120 W to 3.0 kW
• I2t motor thermal protection
• Inverter overload
H x W x D
mm (Inches)
150 x 90 x 116 (5.9 x 3.5 x 4.6)
150 x 90 x 131 (5.9 x 3.5 x 5.2)
150 x 90 x 101 (5.9 x 3.5 x 3.9)
150 x 90 x 101 (5.9 x 3.5 x 3.9)
160 x 140 x 142 (6.3 x 5.5 x 5.6)
181 x 184 x 152 (7.1 x 7.2 x 6.0)
181 x 184 x 152 (7.1 x 7.2 x 6.0)
• earth faults
• motor overtemperature
Approx. Weight
kg (lbs)
Unfiltered
Filtered
0.7 (1.5)
0.8 (1.8)
0.8 (1.8)
0.9 (2.0)
0.6 (1.3)
0.7 (1.5)
0.7 (1.5)
0.8 (1.8)
1.5 (3.3)
1.4 (3.1)
1.9 (4.2)
2.1 (4.6)
2.0 (4.4)
2.2 (4.9)