Table 9-2 Case 1 - General Industrial - Siemens SINAMICS G110 Operating Instructions Manual

120 w - 3 kw
Hide thumbs Also See for SINAMICS G110:
Table of Contents

Advertisement

04/2005
9.1.4 Three general cases of EMC performance are applicable
as detailed below
Case 1: General Industrial
Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3
for use in Second Environment (Industrial) and Restricted Distribution.
Table 9-2
Case 1 - General Industrial
EMC Phenomenon
Radiated Emissions
Emissions
Conducted Emissions
Electrostatic Discharge
Burst Interference
Immunity:
Radio Frequency
Electromagnetic Field
Case 2: Filtered Industrial
This level of performance will allow the manufacturer/assembler to self-certify their
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 50081-2 and EN 61000-6-2.
Table 9-3
Case 2 - Filtered Industrial
EMC Phenomenon
Radiated Emissions
Emissions:
Conducted Emissions
Supply Voltage Distortion
Voltage Fluctuations, Dips,
Unbalance, Frequency
Variations
Immunity:
Electrostatic Discharge
Burst Interference
Radio Frequency
Electromagnetic Field,
amplitude modulated
SINAMICS G110
Operating Instructions
6SL3298-0AA11-0BP0
Electro-Magnetic Compatibility (EMC)
Standard
Level
EN 55011
Level Group 1, Class A
EN 61800-3
Limits are equivalent to EN55011, Class A,
group 2
EN 61000-4-2
8 kV air discharge
2 kV power cables (Level 3), 1 kV control
EN 61000-4-4
(Level 3)
EN 61000-4-3
26-1000 MHz, 10 V/m
Standard
Level
EN 55011
Level Group 1, Class A
Limits are equivalent to EN55011, Class A,
EN 61800-3
group 2
EN 61000-2-4
EN 61000-2-1
EN 61000-4-2
8 kV air discharge
2 kV power cables (Level 3), 2 kV control
EN 61000-4-4
(Level 4)
80-1000 MHz, 10 V/m, 80% AM, power and
EN 61000-4-3
signal lines
75

Hide quick links:

Advertisement

Table of Contents
loading