more secure mounting if needed. Make sure allwires
extend through hole inmounting
base.
7.Adjust length a nd routing o feach w ire to reach proper
connector
block a nd terminal onrear plastic with1/4-in.
extra length. Strip only1/4in. ofinsulation fromeach
wireto prevent adjacent wires fromshorting t ogether
when c onnected.
8.Match a nd connect equipment
wires t oproper terminals
of
each c onnector
block. (See L owVoltage Wiring D iagram
Reference
Chart and Figs. 1through 28inseparate
Wiring
Diagram literature). Remember R andC mustbe
connected for proper o peration. Improper wiringor
installation
may damage Thermidistat
Control. Check t o
make sure wiringis correct before proceeding
with
installation
orturning o npower.
UNIT DAMAGE H AZARD
Failure tofollow this caution may r esult inequipment
damage
orimproper operation.
Improper w iring or installation m ay damage
Thermidistat
Control. Check tomake s ure wiring is
correct before proceeding
withinstallation
orturning
onpower.
9.Push a nyexcess wireintowall a nd against rear p lastic.
Seal hole in wall t oprevent airleaks. Leaks c an affect
operation.
10. R eattach
Thermidistat
Control body t orear plastic byfirst
reattaching
hinge.
11. C lose Thermidistat
Control assembly,
making sure p ins o n
back o fcircuit board a lign w ithsockets
inconnector.
12. T urn onpower toequipment.
Onpower up,alldisplay segments
willlight f or5 sec. Forthe
next 5 sec a 2-digitcode appears onlarge display w hich
identifies
Thermidistat
Control configuration.
1.AC--for l -stage a irconditioner
2.HP--for l -stage heat pump
3.A2--for 2 -stage airconditioner
4.H2--for 2 -stage heat pump
5.dF--for l -stage H ybrid H eat
6.d2--for 2 -stage Hybrid H eat
7.HS--for 1 -stage heat pump w ith Intelligent Heat Staging
(3-stage auxiliary heat with 40FK, FK4C, orFV4A Series
fan coils.)
When t hisidentifier disappears,
normal operation begins. The
MODE c ontrol should beset t oOFF and FAN control toAUTO,
soequipment does n otstart u ntilfurther configuration
and
checkout
iscompleted.
Step
4 --Set
Thermidistat
('ontrol
('onflguration
Configuration
options,
like DIP switch
settings,
are intended
to
be selected
at installation
and normally
are not modified
by the
homeowner.
These options
are not discussed
in the homeowner's
manual
and therefore
must be made as part of the installation.
A
special
procedure
allows
entry
into the
configuration
mode.
While
in configuration
mode,
up to 17 selections
can be made.
Description
of each selection
and how to use the configuration
mode follows.
CONFIGURATION
OPTIONS
-- SUMMARY
Option
1--Anticipator
adjustment
Option
2--Clean
filter timer adjustment
Option
3--English/Metric
selection
Option
4--Fan
(G) ON with W selection
Option
5--Variable-speed
blower
present
selection
Option
6--Cooling
lockout
below 55 ° selection
Option
7--Variable-speed
super dehumidification
selection
(only
available
when variable-speed
blower
is used)
Option
8--Auxiliary
heat
lockout
temperature
setting
(only
available
when heat pump is used)
Option
9--Intelligent
Heat
Staging
selection
(only
available
when single-stage
heat pump is used)
Option
10--Hybrid
Heat
selection
(only
available
when
heat
pump is used)
Option
11--Balance
point
setting
(only
available
when
Hybrid
Heat is selected)
Option
12--Defrost
heat selection
(only
available
when
heat
pump is used)
Option
13--Room
temperature
offset adjustment
Option
14--Heat/cool
dead band adjustment
Option
15--Enable
Auto mode
Option
16--Enables
Super Comfort
Heat Mode
Option
17--Non-Programmable
selection
TO ENTER
CONFIGURATION
MODE
Press and hold FAN button for approximately
10 sec until COOL
set point
display
indicates
a flashing
1. The Thermidistat
Control
is now in configuration
mode.
It will automatically
exit
this mode
if no button
is pressed
for 3 minutes.
Pressing
END
button
will exit configuration
mode
immediately.
WHILE
IN CONFIGURATION
MODE
The
upper
small
(COOL
set point)
display
indicates
selected
option
number
and large display
indicates
selection
made within
that option.
One of these
will be flashing.
The up and down
buttons
are used both to move
between
available
options
and to
make
selection
for each
option.
When
option
number
(small
display)
is flashing,
up and
down
buttons
adjust
it, moving
between
available
option
numbers.
After desired
option
number
has been selected,
press SET TIME/TEMP
button once. The large
display
will now flash, indicating
that up and down
buttons
now
control
available
choices
within
that
option.
Each
press
of
TIME/TEMP
button
switches
between
available
option
(small
display)
and
available
selections
within
each
option
(large
display).
CONFIGURATION
OPTIONS
--SELECTION
Option
1--Anticipator
Adjustment
This adjustment
controls
sensitivity
and cycle rate of Thermidistat
Control.
Higher
numbers
decrease
sensitivity
and slow cycle rate.
Lower
numbers
increase
sensitivity
and cycle rate. However,
a
limiting
feature
'sTill not allow
more
than
4 cycles
per
hr,
regardless
of setting.
Anticipator
values
can range
from
1 to 9.
Factory
default
is 3. This
default
selection
provides
optimum
performance
in nearly
all installations.
Try it first. Do not change
setting
unless
there
is evidence
of need
to do so. Unlike
conventional
anticipators,
this setting is not determined
by current
draw. There
is no need to measure,
know,
or compensate
for
current
draw.
There
is also
no droop
with
this Thermidistat
Control.
Regardless
of setting and number
of stages, both heating
and cooling
will control to their respective
set points.
TO ADJUST
1. Enter configuration
mode
if not already
there. See Step 4
"To Enter Configuration
Mode."
The upper small (COOL
set point)
display
will be flashing
1. If not, use up and
down buttons
to move it to 1.

Advertisement