Single stage heat & cool thermostat 5+2 day (21 pages)
Summary of Contents for Carrier TSTATCCPS101
Page 1
P R O G R A M M A B L E D I G I T A L T H E R M O S T A T Carrier USER INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW THERMOSTAT Heating &...
4 Time Periods ADVANCED SETUP ABOUT ADVANCED OPERATION WARRANTY CAUTION Follow Installation Instructions before proceeding. SET THERMOSTAT TO MODE “OFF” PRIOR TO CHANGING SETTINGS IN SETUP OR RESTORING FACTORY DEFAULTS. Residential Light Commerical Systems Carrier Corporation 4/01 TSTATCCPS101 Page 1...
Front Panel Backlit LCD Display Warmer or + Button 6:03 AUTO Cooler or - Button Mode Button Heat or Cool Indicator Red = Heat, Green = Cool Programmable Thermostat 6:03 AUTO OUTSIDE VACATION PROGRAM SET CLOCK MODE PROGRAM SET CLOCK BACKLIGHT EMERGENCY HEAT Page 2...
Display 12:00 Program Setup Start Locked AUTO Night Morning Evening Fan On Mode Indicators Selects the operation mode of the equipment. HEAT - indicates the heat mode. COOL - indicates the air conditioning mode. AUTO - indicates the system will automatically changeover between heat and cool modes as the temperature varies.
Page 5
Display Morning, Day, Evening & Night Indication Indicates the program time period. Page 8-10. Setup Indication Indicates the thermostat is in the programming mode. Page 6. Fan Operation Indication Fan On - indicates constant, continuous fan operation. When Fan On is not lit - indicates the fan will only operate when necessary to heat or to cool.
Quick Start Set the Clock and Go During Setup & Programming: Press the Set Clock Pressing the Mode button button to enter Setup selects different flashing items. SET CLOCK screens. (Represented in dark black) I2:00 Pressing the Up and Down Setup buttons will modify the flashing selection.
Page 7
Basic Operation Select Mode 12:00 The HEAT setting indicates the temperature the room has to reach before the furnace will Press turn on to heat the room. MODE 12:00 The COOL setting indicates the temperature the room has to reach before the air conditioner will turn on to cool the room.
Basic Operation Select Desired Temperature In any mode, adjust the desired Set Temperature 12:00 with AUTO buttons. Pressing the Up or Down buttons in Auto mode will adjust both the heat and cool set temperatures simultaneously. Pressing the Up or Down buttons in Heat or Cool modes will adjust only the heat or cool set temperature.
Programming 4 Time Periods Press Press the PROGRAM button to enter time period programming. PROGRAM Use the back cover Programming Worksheet to help with this section. 7 30 Start Adjust the start time for Morning. Morning Press MODE 7 30 Adjust the cooling setpoint for Morning.
Page 10
Programming 4 Time Periods I0 30 Start Adjust the start time for Day. Press MODE I0 30 Adjust the cooling setpoint for Day. (35 - 99 ) Press MODE I0 30 Adjust the heating setpoint for Day. (35 - 99 ) Press MODE 5 30...
Page 11
Programming 4 Time Periods 5 30 Adjust the heating setpoint for Evening. (35 - 99 ) Evening Press MODE I I 30 Start Adjust the start time for Night. Night Press MODE I I 30 Adjust the cooling setpoint for Night. Night (35 - 99 ) Press...
Page 12
Advanced Setup Press the Mode button. MODE While holding the Mode, NOTE: Each step # is located at press the Program button the top right corner of the PROGRAM display for easy reference. to enter Setup screens. I2:00 Setup Adjust the time of day clock.
Page 13
Advanced Setup Setup Adjust the deadband from 1 - 6 degrees. Press MODE Setup Adjust the minimum difference between cooling & heating setpoints. (0 - 6 ) Press MODE Setup Select the cycles per hour limit. d=cycles per hour limit defeated. d1=d + defeat 5 min.
Advanced Setup Advanced Setup Table Step # Description Range Factory Default Time of day clock set 24 hour 12:00 Am Heat Pump Off/On Reversing Valve polarity O / B Electric Heat Off / On Deadband 1 - 6 Forced minimum difference heat/cool 0 - 6 Cycles per hour d, d1, 2 - 6...
Page 15
About Advanced Features & Operation MEMORY BACKUP - In the event of a power loss, the thermostat will retain the stored program settings without external power or batteries. 2 STAGE OPERATION - The 2nd Stage of heat is turned on when (1) the 1st Stage has been on for a minimum of two minutes, and (2) the temperature spread from the setpoint is equal to or greater than: the setpoint plus the deadband, plus 2 degrees.
Page 16
About Advanced Features & Operation EMERGENCY HEAT - Is a feature available to Heat Pump installations. To turn on Emergency Heat press in the Fan button. While holding the Fan button press Up button for 2 seconds. The Cool setpoint display will read ‘EH’.
Page 17
About Advanced Features & Operation KEYPAD LOCK - T o prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold in the Mode button. While holding the Mode button in, press the Up and Down buttons in together.
Page 18
About Advanced Features & Operation DUAL SETPOINT BEHAVIOR - The adjustable setpoint range is: 35 - 99 degrees in Fahrenheit and 7 - 35 degrees in Centigrade. When in the modes Heat or Cool, this adjustable range is unhampered. When adjusting any Auto mode, including programming 4 Time periods, the thermostat will not allow the Heat setpoint to get closer to the Cool setpoint...
Page 19
Warranty Five-Year Warranty - This Product is warranted to be free from defects in material and workmanship. If defect appears within five years from the date of original installation, whether or not actual use begins on that date, then the product does meet this warranty. A new or remanufactured part, at the manufacturer’s sole option, to replace any defective part will be provided without charge for the part itself;...