Carrier TSTAT Installation, Start-Up, And Operating Instructions Manual
Carrier TSTAT Installation, Start-Up, And Operating Instructions Manual

Carrier TSTAT Installation, Start-Up, And Operating Instructions Manual

Hide thumbs Also See for TSTAT:

Advertisement

Quick Links

rn to the Expertg_
Installation,
Start-Up,
and
Operating
Instructions
NOTE:
Read
the entire
instruction
manual
before
starting
the
installation.
This symbol
--->indicates
a change since the last issue.
INDEX
Page
SAFETY
CONSIDERATIONS
........................
1
INTRODUCTION
..................................
1
INSTALLATION
CONSIDERATIONS
.................
1
INSTALLATION
...................................
2
HUMIDITY
CONTROL
FEATURES
...................
8
OPERATIONAL
INFORMATION
....................
11
TROUBLESHOOTING
.............................
12
CONFIGURATION
RECORD
........................
13
WIRING
DIAGRAM
....
See Thermidistat
_" Wiring Diagrams
SAFETY CONSIDERATIONS
Read
and follow
manufacturer
instructions
carefully.
Follow
all
local electrical
codes during installation.
All wiring
must conform
to local
and national
electrical
codes.
Improper
wiring
or
installation
may damage Thermidistat
Control.
Recognize
safety
information.
This
is the safety-alert
symbol
z_.
When
you
see this symbol
on the equipment
and in the
instruction
manual,
be alert to the potential
for personal
injury.
Understand
the signal
words
DANGER,
WARNING,
and
CAUTION.
These words
are used with the safety-alert
symbol.
DANGER
identifies
the most serious hazards
which will result in
severe
personal
injury
or death.
WARNING
signifies
a hazard
which
could
result
in personal
injury
or death.
CAUTION
is
used to identify
unsafe
practices
which
would
result
in minor
personal
injury
or product
and property
damage.
NOTE
is used
to
highlight
suggestions
which
will
result
in
enhanced
installation,
reliability,
or operation.
INTRODUCTION
Carrier's
7-day
programmable
/
non-programmable
Thermidistat
_"
Control
is a wall-mounted,
low-voltage
control
which
combines
temperature
and humidity
control
in a single
attractive
unit.
An
extension
of Carrier's
proven
line
of
thermostats,
it provides
separate
set points
for heating
and
cooling,
and now
adds humidification
and dehumidification.
Different
heating
and
cooling
set
points
and
times
are
programmable
for 4 periods
per day and 7 days per week.
The
Thermidistat
Control
can
also
be
field-configured
as a
non-programmable
thermostat.
When
operating
in
the
non-programmable
configuration
it will
still
have
both
temperature
and humidity
control.
Humidify
and dehumidify
\
A98426
Height (In.)
Width (In.)
Depth (In.)
4- 3/8
7 - 3/8
1- 3/8
Fig. 1 - Carrier
Programmable
Thermostat
Control
outputs
provide
direct control of humidity.
Batteries
are not used.
During
power
loss
an internal
memory
stores
programs
and
settings
for unlimited
time, and the clock continues
to run for at
least 8 hr.
INSTALLATION
CONSIDERATIONS
POWER
Note that this control does not require batteries and is not "power
stealing."
It does require 24vac (R and (7 terminals)
of the
low-voltage
transformer
to be connected
to it for proper
operation. It will not operate without these 2 connections.
MODELS
There is a single programmable/non-programmable
model for all
applications. It can be configured for AC or HP, 1-or 2-stage
compressor, and for Hybrid Heat"
installations, allowing it to be
used in place of all Carrier thermostats.
HUMIDIFY EQUIPMENT AND CONNECTIONS
The humidify
output
connects
directly
to 24vac operated
humidifiers. No other connection or interlock is required. Any of
several installer-selectable
operating modes are available.