Clearances To Combustibles (Ul And Ulc); Hearth Pad Requirements (Ul And Ulc) - Quadra-Fire CASTILE-MBK-B Installation Manual

Castile-b pellet appliance
Hide thumbs Also See for CASTILE-MBK-B:
Table of Contents

Advertisement

CASTILE FREESTANDING
B. Clearances to Combustibles (UL and ULC)
A
B
Straight Back Against Wall
A
Back Wall to Appliance
B
Side Wall to Appliance
Corner Installation
C
Walls to Appliance
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
D
F
Vertical Installation
D
Back Wall to Flue Pipe
E
Side Wall to Appliance
F
Back Wall to Appliance
Corner Installation
G
Side Wall to Appliance
Corner
Dimension to Corner
I
Flue Center Line
J
Back of Top Vent Adapter
NOTE:
• Illustrations reflect typical installations and are FOR DESIGN PUR-
POSES ONLY.
Illustrations/diagrams are not drawn to scale.
• Actual installation may vary due to individual design preference.
8
C
Inches
Millimeters
2
51
6
152
Inches
Millimeters
2
51
H
G
E
G
Inches
Millimeters
3
76
6
152
7
178
Inches
Millimeters
2
51
I
J
C L
Inches
Millimeters
10-3/8
264
9-1/8
232
H
Side Wall to Flue Pipe
Alcove Installation
Minimum Alcove Height
Minimum Alcove Side Wall
Minimum Alcove Width
Maximum Alcove Depth
C
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible floor protector, extending beneath
appliance and to the front, sides and rear as indicated. Mea-
sure front distance "M" from the surface of the glass door.
Hearth Pad Requirements
H
K
Sides
L*
Back
M
Front
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible floor protec-
tion is recommended extending beneath the flue pipe when
installed with horizontal venting or under the Top Vent
Adapter with vertical installation.
CANADA INSTALLATIONS: A non-combustible floor pro-
tection extending beneath the flue pipe is required with hor-
izontal venting or under the Top Vent Adapter with vertical
installation.
Fire Risk.
Comply with all minimum clearances to combustibles
as specified. Failure to comply may cause house fire.
7021-154J
3
Inches
Millimeters
43
6
38
36
L*
K
K
M
Inches
Millimeters
2
2
6
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
WARNING
May 12, 2017
76
1092
152
965
914
51
51
152