Company
Note: Whenever the low salt warning lamp is on, the dishwasher will not carry out regeneration.
Air Break Assembly
Located on the right hand side of the
machine.
The Air Break Assembly carries out 3
functions
1. Stops filling water siphoning back into the
mains water supply.
2. Vents the Steam from the dishwasher tub.
3. Diverts 3% of the hard water fill into the
tub to avoid the water being too soft which
could cause excessive foam.
The Air Break also holds the regeneration
valve and the Water fill turbine.
Turbidity Sensor
Situated in the Sump it detects the dirt level in the water and consequently selects the required
cycle content and duration when an Auto Cycle is selected.
The Turbidity Sensor is active on Programmes:
Auto Normal
Auto Duo Wash
Auto Super Wash
Depending upon the soil in the water the control
module, in conjunction with the turbidity sensor
adjusts the following:
Temperature
Cycle duration
Number of rinses
Wash Pump Flexipower Motor speed
Spray arm pressure
Drying
The Natural Drying System uses Residual Heat and Rinse Aid to Dry the loaded dishwasher.
During the Drying Phase of the cycle the Water reaches a very high Temperature 70 ° C.
Drying is carried out in 2 steps both with the machine paused (Circulating wash pump off).
1.
Hot water in the tub.
2.
Hot water drained from the tub.
Filtering System
The flat filter is made of metal and larger than previous models which will prevent the filter from
clogging.
Flat Filter
Service Manual UK
Regeneration
Valve
Bowl Filter
18 of 40
Fill
Turbine
Micro Filter
English