OPERATION CHECK-2
2.CONFIRMATIONS OF OPERATIONS
2-5. CONFIRMATION OF IR OPERATIONS
a. Connect the designated circuit(XANTECH) to IR IN and confirm operations of the unit. (only TX-NR929 except MJJ)
b. Connect the designated circuit(XANTECH) to IR IN A and confirm operations of the unit. (only DTR-60.5/DHC-60.5)
c. Connect the designated circuit(XANTECH) to IR IN B and confirm operations of the unit. (only DTR-60.5/DHC-60.5)
d. Connect the designated circuit(XANTECH) to OUT and confirm operations of the unit.
(only TX-NR929 except MJJ,DTR-60.5/DHC-60.5)
2-6. CONFIRMATION OF RDS (RADIO DATA SYSTEM) OPERATION
(applies to (MMA/MMB/MMP/MMR Type.)
a. Input 98MHz,30dBμ signal modurated with RDS data.
b. When a PS information is received, the name of the station "RDS TEST" shall be displayed within 2 seconds
instead of the frequency.
2-7. CONFIRMATION OF HEAD PHONE OPERATION.
Confirm the Listening Mode is automatically switched to "STEREO" mode when headphones plug is inserted
into the PHONES jack.
2-8. CONFIRMATION OF 12V TRIGGER OPERATIONS .
a. After checking that there is no output from 12V TRIGGER ZONE2(Integra model is TRIGGER A) terminal, confirm that
there is an output of 12V±10%/150mA mmediately switched the "TEST2-11". (except TX-NR929MJJ )
b. After checking that there is no output from 12V TRIGGER ZONE3 (Integra model is TRIGGER B) terminal, confirm that
there is an output of 12V±10%/ 25mA after 2 seconds switched the "TEST2-12".
(except TX-NR929MJJ )
d. After checking that there is no output from 12V TRIGGER C terminal, confirm that
there is an output of 12V±10%/ 25mA after 2 seconds switched the "TEST2-13". (only DTR-60.5/DHC-60.5)
2-9. CONFIRMATION OF OUTPUT VOLTAGE SENSOR AND THERMAL PROTECTOPERATION.(Except DHC-60.5)
a. Set the TEST MODE to "TEST 4-43". Confirm to lit "FM STEREO" on FL displaythe .
Confirm the relays RL6901/6902 is OFF immediately .
b. Push STANDBY/ON button two times while pushing down DISPLAY button to display CPU PROGRAM version.
Push TONE button while displaying CPU PROGRAM version to display value of temparature sensor.
Regarding to "AT" and "DT" of display value, confirm outside temperature ±20C is displayed immediately after energizing.
Note that the error margin is caused by the rise of the temperature of the heat sink when time passes.
No singal condition (Ex. Display)
V:>00 F:x S:H
AT:020
DT:020
V: Output signal level
F: FAN condition
S: Amplifier power supply voltage condition
AT: Temparature sensor of Amplifier
DT: Temparature sensor of HDMI PWB