AXIS T95A00/T95A10 Dome Housing
AXIS 231D+/232D+ and AXIS 233D power connection
1. Unplug the connector from the 12 VDC power supply opposite the bracket opening as shown in
the illustration below.
24V
~
+
~ -
Brown cable
12 VDC
power connector
2. Remove the 2-pin green connector block from the cables.
3. Connect the cable to the camera's power connector as described below:
AXIS 231D+/232D+
AXIS T95A00 Dome Housing (24V DC)
AXIS T95A10 Dome Housing (24V AC)
Connect the brown cable to the 24V AC/DC pins on the AXIS
231D+/232D+ connection module (see illustration).
Note:
The AXIS 231D+/232D+ connection module contains a
rectifier so the cables can be connected either way.
remove green
connector
block
AXIS 231D+/232D+ Connection module
24V AC/DC
Page 7