Mitsubishi Electric FR-E720-0.1K Instructions Manual page 41

Fr-a7np series inverter plug-in option e kit profibus-dp communication function
Hide thumbs Also See for FR-E720-0.1K:
Table of Contents

Advertisement

INVERTER SETTING
(2) Error reset operation selection at inverter fault
When used with the communication option, an error reset command* from network can be made
invalid in the external operation mode or PU operation mode.
Parameter
Number
Communication reset
349
selection
* An error reset command (STW (bit7)) at inverter fault is available with PPO type 1 to 5. (Refer to page 48.)
34
Initial
Name
Value
0
Setting
Range
Error reset* is enabled independently of
0
operation mode
Error reset* is enabled only in the network
1
operation mode
Function