Inlet Filters - Mira Select Flex Installation And User Manual

Thermostatic mixer
Hide thumbs Also See for Select Flex:
Table of Contents

Advertisement

Inlet Filters

The inlet filters should be checked and cleaned
as necessary every 12 months.
Note! The inlet filters must not be removed except
for cleaning. if the thermostatic mixer is operated
without the inlet filters fitted the warranty on the
product will be void.
Exposed Models:
1. isolate the hot and cold water supplies and
operate the flow control lever to drain any
residual water.
2. carefully remove the concealing caps and
unscrew the filter plugs with a 5 mm hexagonal
wrench. Remove the filters.
concealing cap
'o' Seal
3. Clean the filters under a jet of water to remove
any lodged particles.
4. Refit the filters and tighten the filter plugs.
Note! Make sure that the 'O' seal is fitted
correctly and undamaged.
5. turn on the hot and cold water supplies and
check for leaks.
6. Refit the concealing caps.
Built-in Models
1. isolate the hot and cold water supplies and
operate the flow control lever to drain any
residual water.
2. loosen the grubscrew to remove the
temperature control knob. then remove the
flow control lever.
3. carefully unclip the concealing plate from the
backplate.
Note! Use a suitable screwdriver in the cutout
to assist separation.
Filter
Filter Plug
Backplate
cutout
4. Unscrew the two shroud screws and remove
the backplate from the mixer.
5. Unscrew the filter assembly.
6. The filter assembly can be cleaned or replaced
as necessary.
7. Reassemble the filter assembly and screw into
the mixer body.
8. turn on the hot and cold water supplies and
check for leaks.
9. Refit the controls in reverse order.
Note! When refitting the bearing, make sure
that the cutouts are aligned with the control
assembly.
28
concealing Plate
Flow control
lever
Bearing
temperature
control Knob
Filter
Filter assembly

Hide quick links: