Viessmann Vitosol 100-FM Technical Manual page 77

Flat-plate collectors and vacuum tube collectors flat and pitched roof installation, and wall mounting
Table of Contents

Advertisement

DHW cylinders
(cont.)
Pressure drop on the heating water side
500
50
400
40
300
30
200
20
C
100
10
80
8
B
60
6
50
5
40
4
30
3
20
2
10
1
8
0.8
6
0.6
5
0.5
4
0.4
Heating water flow rate in l/h
for one cylinder
A Cylinder capacity 160 and 200 l
B Cylinder capacity 300 l
C Cylinder capacity 500 l
D Cylinder capacity 750 l and 950 l
VITOSOL
Pressure drop on the DHW side
100
10.0
80
8.0
60
6.0
50
5.0
40
4.0
30
3.0
A
20
2.0
D
10
1.0
8
0.8
6
0.6
5
0.5
4
0.4
3
0.3
2
0.2
1
0.1
DHW flow rate in l/h
for one cylinder
A Cylinder capacity 160 and 200 l
B Cylinder capacity 300 l
C Cylinder capacity 500 l
D Cylinder capacity 750 l
E Cylinder capacity 950 l
A
C
B
D
E
VIESMANN
7
77