Vitocell 300-B, Type Evba-A - Viessmann Vitosol 100-FM Technical Manual

Flat-plate collectors and vacuum tube collectors flat and pitched roof installation, and wall mounting
Table of Contents

Advertisement

DHW cylinders

7.4 Vitocell 300-B, type EVBA-A

For DHW heating in conjunction with boilers and solar collectors for
dual mode operation.
Suitable for the following systems:
■ DHW temperature up to 95 °C
■ Heating water flow temperature up to 160 °C
Type
Cylinder capacity
Internal indirect coil
DIN registration number
Continuous output
For DHW heating from 10 to 45 °C and a heating water
flow temperature of ... at the heating water flow rate sta-
ted below
Continuous output
For DHW heating from 10 to 60 °C and a heating water
flow temperature of ... at the heating water flow rate sta-
ted below
Heating water flow rate for the stated continuous outputs
Max. connectable heat pump output
At a heating water flow temperature of 55 °C and a DHW tempera-
ture of 45 °C
For the specified heating water flow rate (both indirect coils connec-
ted in series)
Standby heat loss
Standby capacity V
aux
Solar capacity V
sol
Dimensions
Length a (Ø)
– Incl. thermal insulation
– Excl. thermal insulation
Width b
– Incl. thermal insulation
– Excl. thermal insulation
Height c
– Incl. thermal insulation
– Excl. thermal insulation
Height when
– Incl. thermal insulation
tilted
– Excl. thermal insulation
Weight incl. thermal insulation
Heating water capacity
Heating surface
Connections (male thread)
Indirect coils
7
Cold water, DHW
DHW circulation
Energy efficiency class
Information regarding the upper indirect coil
The upper indirect coil is designed for connection to a heat genera-
tor.
Information regarding the lower indirect coil
The lower indirect coil is designed for connection to solar collectors.
To install the cylinder temperature sensor, use the threaded elbow
with sensor well included in standard delivery.
VIESMANN
56
(cont.)
■ Solar flow temperature up to 160 °C
■ Operating pressure on the heating water side up to 10 bar
(1 MPa)
■ Operating pressure on the solar side up to 10 bar (1 MPa)
■ Operating pressure on the DHW side up to 10 bar (1 MPa)
l
kW
90 °C
l/h
kW
80 °C
l/h
kW
70 °C
l/h
kW
60 °C
l/h
kW
50 °C
l/h
kW
90 °C
l/h
kW
80 °C
l/h
kW
70 °C
l/h
3
m
/h
kW
kWh/24 h
l
l
mm
mm
mm
mm
mm
mm
mm
mm
kg
l
m
2
R
R
R
Information regarding continuous output
When designing systems with the specified or calculated continuous
output, select a matching circulation pump. The stated continuous
output is achieved only if rated boiler heating output ≥ continuous
output.
EVBA-A
EVBA-A
300
upper
lower
upper
Applied for
42
51
1033
1247
1409
35
42
860
1039
1175
28
34
684
827
20
25
501
607
12
15
294
358
36
43
613
740
28
34
482
584
20
24
340
413
3.0
3.0
8.0
1.06
139
161
667
744
1734
1825
113
6.7
11.0
10.0
0.9
1.5
1
1
1
A
500
lower
57
69
1694
48
59
1414
38
46
936
1128
28
34
687
830
16
20
406
493
49
59
838
1011
38
46
662
799
27
33
469
568
3.0
3.0
10.0
1.37
235
265
1022
715
1084
954
1852
1667
1690
123
12.9
1.3
1.7
1
1
A