Viessmann Vitosol 100-FM Technical Manual page 75

Flat-plate collectors and vacuum tube collectors flat and pitched roof installation, and wall mounting
Table of Contents

Advertisement

DHW cylinders
(cont.)
Vitocell 100-V, type CVAA, 750 and 950 l capacity
VA
k
b
o
n
b
Inspection and cleaning aperture
E
Drain
HR
Heating water return
Performance factor N
L
■ To DIN 4708
■ Cylinder storage temperature T
+5 K/-0 K
50 K
Cylinder capacity
Performance factor N
at heating wa-
L
ter flow temperature
90 °C
80 °C
70 °C
Information on performance factor N
The performance factor N
depends on the cylinder storage temper-
L
ature T
.
cyl
Standard values
■ T
= 60 °C → 1.0 × N
cyl
L
■ T
= 55 °C → 0.75 × N
cyl
L
■ T
= 50 °C → 0.55 × N
cyl
L
■ T
= 45 °C → 0.3 × N
cyl
L
VITOSOL
WW
Z
HV/SPR
HR
KW/E
= cold water inlet temperature +
cyl
l
L
HV
Heating water flow
KW
Cold water
SPR Clamping system for fixing immersion temperature sensors to
the cylinder jacket. Fixing points for 3 immersion temperature
sensors
VA
Protective magnesium anode
WW DHW
Z
DHW circulation
Dimensions
Cylinder capacity
Length (7)
Width
Height
Excl. thermal insulation
Excl. thermal insulation
160
200
300
2.5
4.0
9.7
2.4
3.7
9.3
2.2
3.5
8.7
l
750
a
mm
1062
b
mm
1110
c
mm
1897
d
mm
1788
e
mm
1179
f
mm
916
g
mm
377
h
mm
79
k
mm
555
l
mm
7 180
m
mm
513
n
mm
1005
o
mm
7 790
500
750
21.0
38.0
19.0
32.0
16.5
25.0
VIESMANN
950
1062
1110
2197
2094
1283
989
369
79
555
7 180
502
1005
7 790
950
7
44.0
42.0
39.0
75