Siemens RUGGEDCOM WIN5237 Installation Manual page 20

Table of Contents

Advertisement

Chapter 2
Installing the Subscriber Station
Figure 5: Mounting the Subscriber Station to a Small Pole
1. Subscriber Station    2. Pole    3. Clamping Bracket    4. Mounting Bracket    5. M8-25 Hex Screw    6. M8 Spring Washer    7. M8 Flat
Washer    8. M8 Nut    9. M8-70 Hex Screw
2.
Liberally apply an anti-corrosion spray to all galvanized steel components, including mounting brackets, nuts,
washers and screws.
3.
Select a mounting location on the pole.
4.
Position the mounting bracket against the pole.
NOTE
When mounting the subscriber station, note the orientation of the clamping bracket in
Figure
5.
Secure the clamping bracket to the mounting bracket using screws, spring washers and nuts. Make sure the
screws are hand tightened.
6.
Point the front face of the subscriber station in the general direction of the designated base station.
7.
Make sure the PWR LED on the subscriber station is on.
8.
Position the subscriber station until the maximum RSSI link quality reading is achieved. A single RSSI LED
indicates the subscriber station is at minimum synchronized with the base station. For information about the
RSSI LED indicators, refer to
If the subscriber station is not synchronized with the base station, make sure the subscriber station is properly
configured. For more information, refer to the RUGGEDCOM WIN CPE User Guide.
If the expected link quality still cannot be achieved, try to improve the reception quality by placing the
subscriber station at a higher point or in an alternate location.
9.
Make sure the subscriber station is properly grounded according to local standards. For more information,
refer to
Section 2.7, "Grounding the Subscriber
14
4
3
5
6
7
5.
Section 1.2,
"Description".
8
Station".
Installation Guide
6
7
Mounting the Subscriber Station to a Pole
RUGGEDCOM WIN5237
1
2
3
9
6
7
Figure 4
or

Advertisement

Table of Contents
loading

Table of Contents