Adjustments - Furuno RD-50 Operator's Manual

Hide thumbs Also See for RD-50:
Table of Contents

Advertisement

Connection of WAGO connector
Remove the WAGO connector from each unit and connect each cable core to the
WAGO connector. See the interconnection diagram (page S-1). The terminal opener
is attached inside the remote display at the location shown in the illustration below.
Cable
entrance
Remote display (Rear view)
4.6

Adjustments

After wiring all units, initialize each remote display as follows:
1. While you hold down the DISP key, press the PWR key to turn on the power.
2. Press
3. Press
4. Repeat steps 2 and 3 to set the menu items desired.
5. Press the PWR key to close the service menu and turn off the power.
WAGO connector
Fuse
Terminal
opener
Ground
terminal
Service menu
or
key to select a menu item and press the ENT key.
or
key to select an option and press the ENT key.
How to connect wires to WAGO connector
Press downward.
Wire
WAGO connector
Twist
Procedure
1. Twist the cores.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
XXXX
XXXX: Serial number
XX: Program version number
4. INSTALLATION
Terminal opener
4-13

Advertisement

Table of Contents
loading