Standalone System (Sal); Operating Precautions - Olympus DP21 Instructions Manual

Microscope digital camera
Hide thumbs Also See for DP21:
Table of Contents

Advertisement

STANDALONE SYSTEM (SAL)

Read this chapter if you use the camera head by connecting it to the control box.

2-1 Operating Precautions

System Compatibility
· Only the following USB devices function when connected to the control box, etc.
Connectable USB devices: USB removable media such as a USB memory
· Even when one of the USB devices is used, it cannot be connected if it needs a special driver or the Explorer function
of the PC for operation.
· When a USB device with current consumption above 200 mA (including a USB memory, mouse or keyboard) is
connected, it may not function due to insufficient power supply from the hand switch.
· The network connection requirements are as follows.
Applicable PC: DOS/V AT compatible machine
Applicable OS: Windows XP Professional/Vista Business (32-bit)/Vista Ultimate (32-bit)
Standards: IEEE802.3 (10BASE-T Ethernet),
IEEE802.3u (100BASE-TX Fast Ethernet) compliant
Applicable protocol: TCP/IP (Incompatible with IPv6)
Connector: RJ-45 type 8-pole connector
Transmission rate: 10 Mbps (10BASE-T Ethernet)/100 Mbps (100BASE-TX Fast Ethernet)
Even when the connection requirements above are met, connection and operation in any network environment is not
guaranteed.
Computer Virus Note
As a countermeasure against computer viruses, the DP21 is set to inhibit write of foreign files in the system domain.
Nevertheless, it is not capable of preventing infection by computer viruses that are evolving day by day. To prevent
penetration of computer viruses in the DP21, it is also recommended to take the following countermeasures.
· Perform virus check on the removal medium, such as a USB memory, before connecting it to the DP21. (The DP21
does not have the virus check function. Use your PC for virus checking.)
· Ensure that the network and PC to which the DP21 is connected are free of computer viruses.
· Should infection of a computer virus occur or be suspected, turn the control box of the DP21 OFF and unplug its
power cord. This clears the RAM and deletes any foreign files.
· If malfunction or a symptom of infection still persists after the above measure, please consult Olympus.
Olympus will not assume any liabilities for a malfunction of the DP21 due to computer viruses as well as any trouble or
damage of the user's PC or network incurred due to computer viruses.