Troubleshooting; Warranty - Delta BreezRadiance RAD110LED Instructions Manual

Ventilation fan with led light and heater
Table of Contents

Advertisement

TROUBLESHOOTING

PROBLEM
The fan is not turning on
The fan seems louder
than it should
The fan is not clearing
the room
The light is not turning on
The heater is not heating
than it should

WARRANTY

DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. ("Delta Electronics") warrants to the original consumer purchaser in the USA that the Breez ventilation fan
products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of
purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer.
The warranty provided herein does not cover charges for labor or other costs incurred in the troubleshooting, repair, removal, and
installation service.
2. All returns of defective parts or products must include the product model number, and must be made through an authorized Delta
Electronics distributor. Authorized returns must be shipped prepaid. Repaired or replacement products will be shipped by Delta
Electronics F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, incidental, consequential, punitive, or special damages arising out of or in
connection with products use or performance, regardless of the form of action whether in contract, tort (including negligence), strict
product liability or otherwise.
4. This warranty does not extend to fluorescent lamp starters and tubes.
5. The warranty does not cover if user does not comply with manufacturer's installation manual.
6. To qualify for warranty service, you must notify Delta Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original owner-user with respect to any defect caused by abuse, misuse, neglect,
improper transportation or storage, improper testing, improper installation, improper operation, improper use, improper maintenance,
improper repair, improper alteration, improper modification, tempering or accident of products or parts thereof, or unusual
deterioration or degradation of products or parts thereof due to a physical environment beyond the requirements of products'
specifications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
www.deltabreez.com
POSSIBLE CAUSE
1. Power off
2. Faulty switch
3. Faulty wire connection
1. CFM is too great
2. Damper not working properly or
damaged
3. Bend in duct too close to fan
discharge
4. Fan discharge reduced to fit
smaller duct
5. Fan body not securely attached
1. Insufficient intake airfow within
room
2. Insufficient CFM
1. Power off
2. Faulty switch
3. Faulty wire connection
1. Faulty switch
2. Faulty wire connection
3. Filter is not clean
CORRECTIVE ACTION
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
1. Be sure CFM rating on the fan matches the size of your room.
2. Be sure damper is opening and closing properly. If the damper
has become damaged, please call Customer Service.
3. Be sure you do not have any sharp bends in duct closer than
18 in. to the fan discharge.
4. Use recommended size ducting to reduce fan noise.
5. Be sure the fan is securely attached to your ceiling joists.
1. Be sure a door or window is slightly ajar or opened to allow
airflow. The fan is not able to draw air out of the room without
enough airflow to draw in from.
2. Be sure the CFM rating on the fan matches the requirements
for your room size.
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
1. Test or replace switch.
2. Check wire in switch box.
3. Remove dust from filter.