2.5 Power board, connections and probes

Sensor Test Table (ohmic resistance values as a function of temperature)
T [°C]
R [kΩ]
T [°C]
-40
195,7
-10
-35
148,2
-5
-30
113,3
0
-25
87,6
5
-20
68,2
10
-15
53,6
15
R [kΩ]
T [°C]
R [kΩ]
42,5
20
12,1
33,9
25
10,0
27,2
30
8,3
22,0
35
6,9
17,9
40
5,8
14,7
45
4,9
main power board (PCB)
power cable (PCB - HE1: red; PCB - HE2: blue)
HE1 probe with cable (width = 8 mm)
HE2 probe with connector (width = 6,5 mm)
HE2 probe cable
T [°C]
R [kΩ]
T [°C]
50
4,2
55
3,5
60
3,0
65
2,6
70
2,2
75
1,9
8
R [kΩ]
T [°C]
80
1,7
110
85
1,5
115
90
1,3
120
95
1,1
125
100
1,0
105
0,9
R [kΩ]
0,8
0,7
0,6
0,5