Cable Lengths - Siemens SCALANCE XR324-4M EEC Operating Instructions Manual

Scalance xr-300m eec series. industrial ethernet switches
Hide thumbs Also See for SCALANCE XR324-4M EEC:
Table of Contents

Advertisement

6.3

Cable lengths

Table 6- 12
Cable type
IE TP torsion cable
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
IE FC TP standard cable
Table 6- 13
Cable type
IE FC Standard Cable, 4 × 2, 24
AWG
IE FC Flexible Cable, 4 × 2, 24
AWG
IE FC Standard Cable, 4 × 2, 22
AWG
IE FC Flexible Cable, 4 × 2, 22
AWG
Note
Permitted cable lengths (fiber-optic cable - Fast Ethernet or gigabit)
The values correspond to those of the permitted MM900 media modules and SFP
transceivers.
SCALANCE XR-300M EEC
Operating Instructions, 11/2015, A5E02661176-09
Permitted cable lengths (copper cable - Fast Ethernet)
Accessory (plug, outlet,
TP cord)
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC RJ-45 Plug 180
Permitted cable lengths (copper cable - gigabit Ethernet)
Accessory (plug, outlet,
TP cord)
with IE FC RJ-45 Plug 180,
4 × 2
with IE FC Outlet RJ-45
+ 10 m TP cord
with IE FC Outlet RJ-45
+ 10 m TP cord
Technical data
6.3 Cable lengths
Permitted cable length
0 to 45 m
+ 10 m TP cord
0 to 55 m
0 to 75 m
+ 10 m TP cord
0 to 85 m
0 to 90 m
+ 10 m TP cord
0 to 100 m
Permitted cable length
0 to 90 m
0 to 60 m
+ 10 m TP cord
0 to 90 m
+ 10 m TP cord
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents