Minimum clearances
If you install the IE Switch in rack devices without forced ventilation or cooling, minimum
clearances must be maintained to neighboring devices or the wall of the enclosure. By
keeping to the minimum clearances, there is then an adequate stream of air for heat
dissipation during operation. Keep to the following minimum clearances to neighboring
devices.
Table 4- 1
Minimum clearance to devices below the switch
Minimum clearance to devices above the switch
NOTICE
Four-point mounting
If mechanical load is high, the device should be secured at four points. You will find more
detailed information in the section "Mechanical stability in operation".
Normal orientation
Normal orientation of the device
The LED display is on the left of the front panel of the hous-
ing.
The Ethernet ports or the slots for the modules are also on
the front of the housing. Slots for the modules are fitted with
dummy covers.
The C-PLUG is on the right behind a protective panel se-
cured with screws.
(For more detailed information, refer to the section on the C-
PLUG in the X-300 operating instructions.)
The ventilation grilles are on the top, bottom and sides of the
housing.
On the rear of the device, you will find the diagnostics port.
The grounding bolt and the connectors for the signaling
contact and power supplies are also on the rear of the de-
vice.
Note that there are different power supplies (see section
"XR-300M EEC product group (Page 6)").
SCALANCE XR-300M EEC
Operating Instructions, 11/2015, A5E02661176-09
Minimum clearances for installation in rack devices
4.2 19" rack mounting - XR-300M EEC product group
SCALANCE XR324-4M EEC
SCALANCE XR324-4M EEC
Assembling
100 mm
100 mm
25