Maintenance - Filters; Maintenance - Motorised Floor Brush - Morphy Richards SuperVac 732102 Instruction Book

2-in-1 cordless bagless upright vacuum cleaner
Table of Contents

Advertisement

VC732102 MUK Rev1.qxp_Instruction Book 14/11/2016 09:28 Page 9

Maintenance - filters

The guarantee may be invalidated if the motor
is damaged due to: using the appliance
without the filters installed; not cleaning the
filters; or not replacing a damaged filter.
Cleaning the dust canister filters
To maintain suction, the individual parts of the
dust canister filter holder assembly
be cleaned each time the dust canister
emptied.
Follow steps 1-4 of 'Emptying the dust canister'.
1.
Pull the pleated filter
2.
holder assembly
anti-clockwise, then pulling it away from the
cyclone cone (18a).
18a
Every month, wash the pleated filter
3.
luke-warm water and thoroughly air dry before
re-fitting, as well as cleaning the cyclone cone
(18a).
IMPORTANT: Do not wash the filters with hot
water or detergents.
IMPORTANT: Do not use heated appliances to
dry the filters.
Fit all parts of the dust canister filter holder
4.
assembly
(18)
back together, then refit back into
the dust canister (17), then replace the dust
canister back onto the handheld vacuum cleaner.
Replace the handheld vacuum cleaner back into
5.
the main vacuum cleaner body
cleaning.
Maintenance - motorised
floor brush
If the motorised floor brush
eg. by a foreign object or if used on very deep
pile carpet, switch off, remove the cause of the
stall, and leave for a few minutes to allow the
floor nozzle protection to self reset.
(18)
must
(17)
(18b)
out from the filter
(18)
by slightly twisting it
18
18b
(18b)
in
(11)
if upright
(21)
is stalled,
To clean the motorised floor brush, you must
remove the handheld vacuum cleaner as shown
in 'Handheld vacuum cleaning', page 7. Then,
press the floor brush release button
the motorised floor brush away.
is
Turn the motorised floor brush
inspect the rotating brush bar (21c).
3
Push the locking button
cover
(21b)
forward to unlock the cover.
21a
Open the brush bar cover
brush bar
(21c)
out. Pull away any hairs or fibres
from the rotating brush bar, checking especially
around the ends of the brush bar. If they are tightly
wound around the brush, carefully snip the fibres
with scissors, being careful not to damage the
rotating brush bar, pull away from the rotating
brush bar and dispose of. Also, check for any
blockages to the floorhead suction inlet - if any are
noted, clear before replacing the rotating brush
bar. Replace the rotating brush bar and brush bar
cover in their original position and re-lock the
locking button (21a).
21b
(20)
and pull
3
(21)
over to
(21a)
on the brush bar
4
21b
21c
(21b)
and lift the rotating
5
21c
9