Initial Start-Up Procedure- Supervisor; Subsequent Start-Up Procedure- Supervisor; Shutdown Procedure- Supervisor - Sullair LS-100L Operator's Manual

Ls-100 series industrial air compressor 25, 30 & 40 hp/ 18, 22 & 30 kw standard & 24 kt air-cooled and water-cooled
Table of Contents

Advertisement

6.9 SUPERVISOR II OUTPUT RELAYS (CONTINUED)
RELAY
COMMON FAULT (K4)
DRAIN VALVE (K5)
FULL LOAD/MODULATE (K6)
NOTE: All output relays will handle eight (8) amps at 120/240 VAC.
6.10 INITIAL START-UP PROCEDURE- SUPERVI-
SOR II
The following procedure should be used to make
the initial start-up of the compressor.
1. Read the preceding pages of this manual thor-
oughly.
2. Jog motor to check for correct rotation of motor
(refer to Section 4.8).
3. Be sure that all preparations and checks
described in the Installation Section have been
made.
4. Open the shut-off valve to the service line.
5. Check for possible leaks in piping.
6. Slowly close the shut-off valve to assure proper
nameplate pressure unload setting is correct.
The compressor will unload at nameplate pres-
sure. If adjustments are necessary, see
System
Adjustments.
OPERATION
May be used to provide remote indication of any pre-
alarm, maintenance or fault shutdown condition.
Controls solenoid valve to provide automatic conden-
sate removal.
Used with optional sequencing feature.
7. Observe the operating temperature. If the oper-
ating temperature exceeds 200ºF (93ºC), the
cooling system and installation environment
should be checked.
8. Open shut-off valve to the service line.
9. Reinspect the compressor for temperature and
leaks the following day.
6.11
SUBSEQUENT
SUPERVISOR II
On subsequent start-ups, check that the proper
level is visible in the fluid level sight glass and sim-
ply press "
matic operation. When the compressor is running,
observe the various parameter displays.
6.12 SHUTDOWN PROCEDURE- SUPERVISOR II
To shut the compressor down, push "
Control
Section 6
SUPERVISOR II
START-UP
PROCEDURE-
" for manual or "
" for auto-
" pad.