Ping Check; Figure 6: Timos Boot - System Initialization - Part Iii - Alcatel-Lucent 7210 SAS M Basic System Configuration Manual

7210 series service access switch
Hide thumbs Also See for 7210 SAS M:
Table of Contents

Advertisement

Configuration and Image Loading

Ping Check

If the system is booted up using the auto-init procedure, the runtime image performs a ping check
to make sure that the system has IP connectivity. The runtime image, after loading the
configurations from the configuration file, tries three times to ping the IP address specified as the
ping-address parameter in the BOF file, at a 2, 8 and 16 minutes interval minute interval. If the
ping does not succeed, the system is rebooted with BOF reset after 1 minute and the whole boot
process is repeated. If address in the BOF is zero or the ping address is not given, the ping check is
not done.
Three Trials
With 5 Mins
Interval
Page 100
Figure 6
describes the TiMos Boot — System Initialization Part III.
TIMOS
T
Boot Up
Load TIMOS
Bootstrap-updated Flag Set,
Mark It As Success
Apply Downloaded Configuration
Booting For
First-time Or Booting After
Reset-to-factory
Default?
Yes
Ping Safe-boot IP If Configured
In BOF
PING Reply
Received For
Safe-boot IP?
Yes
BOOT Process Complete.
Send Trap To SNMP.
Issue Trap.
Issue Log Entry.
Issue Console Msg.

Figure 6: Timos Boot - System Initialization - Part III

7210 SAS M, X Basic System Configuration Guide
BOOT Process Complete.
Send Trap To SNMP.
No
Issue Trap.
Issue Log Entry.
Issue Console Msg.
No
Reset Factory Default, Reboot