falling-threshold threshold — Specifies a threshold for the sampled statistic. When the current
owner owner — The owner identifies the creator of this alarm. It defaults to "TiMOS CLI". This
Configuration example:
alarm 3 variable-oid ifInOctets.184582144 interval 20 sample-type delta start-alarm
either rising-event 5 rising-threshold 10000 falling-event 5 falling-threshold 9000
owner "TiMOS CLI"
cflash-cap-alarm
Syntax
cflash-cap-alarm cflash-id rising-threshold threshold [falling-threshold threshold]
interval seconds [rmon-event-type] [startup-alarm alarm-type]
no cflash-cap-alarm cflash-id
Context
config>system>thresholds
Description
This command enables capacity monitoring of the compact flash specified in this command. The
severity level is alarm. Both a rising and falling threshold can be specified.
The no form of this command removes the configured compact flash threshold alarm.
Parameters
cflash-id — The cflash-id specifies the name of the cflash device to be monitored.
rising-threshold threshold — Specifies a threshold for the sampled statistic. When the current
7210 SAS M, X Basic System Configuration Guide
sampled value is less than or equal to this threshold, and the value at the last sampling interval
was greater than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is less than or equal to
this threshold and the associated 'startup-alarm' is equal to 'falling' or 'either'.
After a rising threshold crossing event is generated, another such event will not be generated
until the sampled value rises above this threshold and reaches greater than or equal the rising-
threshold threshold value.
Default
0
Values
-2147483648 — 2147483647
parameter is defined primarily to allow entries that have been created in the RMON-MIB
alarmTable by remote SNMP managers to be saved and reloaded in a CLI configuration file. The
owner will not normally be configured by CLI users and can be a maximum of 80 characters
long.
Default
TiMOS CLI
Values
cf1:, cf1-A:
sampled value is greater than or equal to this threshold, and the value at the last sampling interval
was less than this threshold, a single threshold crossing event will be generated. A single
threshold crossing event will also be generated if the first sample taken is greater than or equal to
this threshold and the associated 'startup-alarm' is equal to 'rising' or 'either'.