5.15
Heater function
The heating element 1 has two integrated fuses 2(boil-dry protection).
The fuses cannot be changed.
1
Heating elements
2
Integrated fuses
3
NTC (resistance with negative temperature coefficient)
209_58300000178575_ARA_EN_C.doc – 30.06.2015
5.16
Water level sensor system function
The sensor system consists of a hose, giver housing and analogue
sensor.
5.16.1 Analogue sensor
The analogue sensor is based on the piezo-electric principle and
emits a voltage between 0.5 V = and 3.5 V =. There is no point in
measuring the emitted direct voltage as the analogue value in the
customer-service test programme is indicated on the display. The
analogue sensor is responsible for the different water levels in the
various wash programmes.
4
Connecter plag
5
Analogue sensor
Page 31 de 70