System Battery - HP ProLiant XL730f Gen9 User And Maintenance Manual

Hide thumbs Also See for ProLiant XL730f Gen9:
Table of Contents

Advertisement

Install the heatsink.
6.
Install the access panel (on page 12).
7.
Install the server
8.
Connect all peripheral cables to the server.
9.
Power up the server
10.

System battery

If the server no longer automatically displays the correct date and time, you might have to replace the battery
that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.
WARNING:
pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not
properly handled. To reduce the risk of personal injury:
Do not attempt to recharge the battery.
Do not expose the battery to temperatures higher than 70°C (158°F).
Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.
Replace only with the spare designated for this product.
IMPORTANT:
configuration. After replacing the battery, reconfigure the system through RBSU.
To remove the component:
Power down the server (on page 9).
1.
Disconnect all peripheral cables from the server.
2.
Remove the server (on page 10).
3.
Remove the access panel (on page 11).
4.
Locate the battery on the system board
5.
("Installing the
server" on page 14).
("Powering up the
server" on page 14).
The computer contains an internal lithium manganese dioxide, a vanadium
Replacing the system board battery resets the system ROM to its default
("Server
components" on page 7).
Removal and replacement procedures 52