Troubleshooting Guide - Thermador UCV30 Use And Care Manual

Universal cook‘n’vent downdraft system
Hide thumbs Also See for UCV30:
Table of Contents

Advertisement

Top cap is not removable. Wash top and underside with hot sudsy water. Rinse and wipe dry or
Anodized
apply Fantastic
Aluminum
Top Cap for
NOT USE powdered cleansers or steel wool pads.
Stainless
Aluminum
Clean filters in the dishwasher or by agitating in sudsy water. Ensure that there is no soil
Mesh Filters
trapped in the fine mesh. Dry the filters before reinstalling them.
Plastic
Wipe with a moist soapy sponge. Rinse and dry. DO NOT USE powdered cleansers or steel
Up/Down
wool pads.
button and,
Controls
Top cap is not removable. Wash top and underside with hot sudsy water. Rinse and wipe dry or
Painted
Top Cap for
apply Fantastik
Black/White
NOT USE powdered cleansers or steel wool pads.
Stainless
Wipe grease accumulation with a paper towel or sponge. Scrape heavy buildup with a plastic
Steel
spatula. Clean with a soapy sponge; rinse and dry. Always wipe or rub with grain. Wipe with
Filter Front
Fantastik
& Back Wall
applications may be necessary.
Polish with Stainless Steel Magic
dampened with white vinegar. Use Cameo Aluminum and Stainless Steel Cleanser

TROUBLESHOOTING GUIDE

PROBLEM
Intake Stopped
Nothing works - all buttons are
illuminated.
Nothing works - no buttons are
illuminated.
Clean Filter Reminder button illu-
minates
CARE AND CLEANING
®
or Formula 409
®
first to a clean sponge or paper towel and wipe clean. DO
®
or Formula 409
®
first to a clean sponge or paper towel and wipe clean. DO
®
®
or Formula 409
sprayed onto a paper towel. If grease buildup is heavy, several
®
POSSIBLE CAUSE
Obstruction
Intake encountered an obstruc-
tion on the way up & timed out.
Control button board has become
disconnected.
PAGE 6
and a soft cloth. Remove water spots with a cloth
REMEDY
Remove obstruction, press Snor-
kel Up/Down button to raise in-
take, then press again to lower
intake.
Reactivate the controls by press-
ing the Delay Shut Off button and
then the Blower Off button. Press
the Snorkel Up/Down button to
continue operation. If intake is
so low that control buttons are
not accessible, reset by unplug-
ging and plugging.
*If problem persists, leave intake
in the current position and con-
tact electrician or qualified appli-
ance service technician.
Contact qualified appliance service
technician.
Clean filters, then press and hold
the Clean Filter Reminder button
for three seconds to reset.
®
.