CS-SA18CKP / CU-SA18CKP5
8.6.
Connecting piping and the cable to outdoor unit
8.6.1.
Connecting the piping to outdoor unit
1. Align the center of the piping and sufficiently tighten the flare nut with fingers.
2. Finally tighten the flare nut with torque wrench until the wrench clicks.
" When tightening the flare nut with torque wrench, ensure the direction for tightening follows the arrow of the wrench.
3. Ensure not to let the piping exposed to air.
8.6.2.
Connecting the cable
1. Remove the top cover from the unit by loosening the four screws.
2. Remove the control board cover by loosening the screw.
3. Connect the locally approved cable (1.5mm
4. Secure the cable onto the control board with the holder (clamper).
5. Attach the control board cover and the top cover to the original position with the screws.
Model
Piping side
CS-SA18CKP/ CU-
Liquid side 1/4"
SA18CKP5
Gas side 1/2"
Caution
When connecting the piping, always use a torque wrench. Other
tools may cause damage to the flare nut because of improper
force.
2
) to the terminals on the control board individually.
Torque
18N.m
55N.m