CS-SA18CKP / CU-SA18CKP5

8 Installation

8.1.
Before Installation
WARNING
! Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical
shock or fire.
! Use the specified cable(1.5mm
! Power supply connection to a circuit breaker for the permanent connection. Use an approved 10A circuit breaker for the
permanent connection. It must be a double pole switch with a minimum 3 mm contact gap.
! The unit must be earthed, or it will cause fire or electric shock.
SELECT THE BEST LOCATION
INDOOR UNIT
• • • • There should not be any heat source or steam near the unit.
• • • • There should not be any obstacles blocking the air circulation.
• • • • A place where air circulation in the room is good.
• • • • A place where drainage can be easily done.
• • • • A place where noise prevention is taken into consideration.
• • • • Do not install the unit near the door way.
• • • • Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
• • • • Recommended installation height for indoor unit shall be at least 2.3m.
OUTDOOR UNIT
• • • • If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not
obstructed.
• • • • There should not be any animal or plant which could be affected by hot air discharged.
• • • • Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
• • • • Do not place any obstacles which may cause a short circuit of the discharged air.
• • • • If piping length is over the common length, additional refrigerant should be added.
2
) and connect tightly for indoor/outdoor connection.
22