SPECIFICATIONS

Model name (Service Ref.)
Overall unit dimensions
Weight (empty)
Weight (full)
Water volume of heating circuit in the unit
Cooling mode
Nominal volume
Unvented expansion
vessel(Primary heating)
Charge pressure
Control thermistor
Water
circuit
Pressure relief valve
Safety
(Primary)
Flow sensor
device
Manual reset thermostat
Booster
heater
Thermal Cut-out (for dry run prevention)
Primary circuit circulating Pump
Water
Connections
Refrigerant (R410A)
Flow temperature
Target temperature
range
Room temperature
Ambient *
Guaranteed operating
range
Outdoor temperature
Control board
Electrical data
Booster heater
Sound level
*1 The environment must be frost-free.
*2 Cooling mode is not available in low outdoor temperature.
If you use our system in cooling mode at the low ambient temperature (10°C or below), there are some risks of plate heat exchanger breaking by frozen water.

Optional extras

● Wireless Remote Controller
PAR-WT50R-E
● Wireless Receiver
PAR-WR51R-E
● Remote Sensor
PAC-SE41TS-E
● Tank thermistor (THW5) (5 m)
PAC-TH011TK-E
● Joint pipe
MAC-A454JP-E
OCH590B
Liquid
Gas
Heating
Cooling
Heating
Cooling
1
Heating
Cooling
Power supply
(Phase, voltage, frequency)
Breaker (when powered
from independent source)
Power supply
(Phase, voltage, frequency)
Capacity
Current
Breaker
● Tank thermistor (THW5) (30 m)
● Thermistor
● High temperature thermistor
● ecodan Wi-Fi Interface
EHSE-YM9EC.UK
EHSE-MEC.UK
950 × 600 × 360 mm (Height × Width × Depth)
62 kg
60 kg
72 kg
70 kg
NOT available
0.3 MPa (3bar)
Min. flow 5.0 L/min
90°C
121°C
Grundfos UPMXL GE0 25 - 125 180PWM
0–35°C ( 80%RH)
See outdoor unit spec table.
~/N, 230 V, 50 Hz
3~, 400 V,
50 Hz
3 kW+6 kW
13 A
16 A
PAC-TH011TKL-E
PAC-TH011-E
PAC-TH011HT-E
PAC-WF010-E
6
ERSE-YM9EC.UK
ERSE-MEC.UK
63 kg
61 kg
73 kg
71 kg
10 kg
Available
1–80°C
90°C
121°C
G1-1/2
3/8 F
3/4 F
25–60°C
5–25°C
10–30°C
NOT available
See outdoor unit spec table
2
(min. 10°C). *
10 A
3~, 400 V,
50 Hz
3 kW+6 kW
13 A
16 A
30 dB(A)