FIELD WIRING

Breaker abbreviation
Meaning
ECB1
Earth leakage circuit breaker for booster heater
TB1
Terminal block 1
Option 1: Hydrobox powered via outdoor unit
<1 phase>
Affix label A that is included with the manuals near each wiring diagram for hydrobox and outdoor units.
Power
Earth
supply
leakage
~/N
circuit
230 V
breaker
1,
2
*
*
50 Hz
Electrical connections 1 phase
<3 phase>
Affix label A that is included with the manuals near each wiring diagram for hydrobox and outdoor units.
Earth
Power
leakage
supply
circuit
3N~
breaker
400 V,
1,
2
*
*
50 Hz
Power supply
3~ 400 V, 50 Hz (E*SE-YM9EC)
Electrical connections 3 phase
Hydrobox - Outdoor unit
Hydrobox - Outdoor unit earth
Hydrobox - Outdoor unit S1 - S2
Hydrobox - Outdoor unit S2 - S3
2
A breaker with at least 3.0 mm contact separation in each pole shall be provided. Use earth leakage breaker (NV).
*
The breaker shall be provided to ensure disconnection of all active phase conductors of the supply.
3
Maximum 45 m
*
If 2.5 mm² is used, maximum 50 m.
If 2.5 mm² is used and S3 is separated, maximum 80 m.
4
The values given in the table above are not always measured against the ground value.
*
Notes:
1. Wiring size must comply with the applicable local and national codes.
2. Indoor unit/outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60245 IEC 57)
Indoor unit power supply cords shall not be lighter than polychloroprene sheathed flexible cord. (Design 60227 IEC 53)
3. Install an earth longer than other cables.
4. Please keep enough output capacity of power supply for each heater. Insufficient power supply capacity might cause chattering.
OCH590B
Outdoor unit
L
S1
Wiring
circuit
N
S2
breaker or
Isolating
S3
switch
<Figure 7-1>
Outdoor unit
L1
L2
Wiring
circuit
L3
breaker or
Isolating
N
switch
Wiring
circuit
breaker or
Isolating
switch
<Figure 7-2>
3
3 × 1.5 (polar)
*
3
*
*
4
4
*
Hydrobox
TB1
L
N
To control
board
S1
S2
S3
Hydrobox
TB1
L1
L2
To control
board
S1
S1
S2
S2
S3
S3
ECB1
L1
For
booster
L2
heater
(Primary circuit)
L3
1 × Min. 1.5
230 V AC
24 V DC
16
I f the installed earth leakage circuit breaker does
* 1
not have an over-current protection function, install a
breaker with that function along the same power line.
If the installed earth leakage circuit breaker
*
1
does not have an over-current protection
function, install a breaker with that function
along the same power line.
Description
Power supply Capacity Breaker Wiring
Booster heater
3~ 400 V
9 kW
(Primary circuit)
50 Hz
2.5
16 A
2
*
mm²