➜
disarming diagnostics
Extra chirps that are heard when disarming the system are the
Tamper Alert. If four chirps are heard when disarming the
system, then the security system was triggered in your absence. If
five chirps are heard when disarming the system, a zone was trig-
gered so many times that the Nuisance Protection
bypassed that zone. In either case, the status LED will indicate
which zone was involved (see Table of Zones section). The secu-
rity system will retain this information in its memory and chirp
four or five times each time it is disarmed, until the next time
that the ignition is turned on.
➜
system status chirps
The siren will chirp when arming/disarming the system. The
pattern of chirps will audibly report the system's status as
described below.
Action
Arm
Arm
Disarm
Disarm
Disarm
© 2008 directed electronics—all rights reser ved
Number of Chirps
1
1 (3-second delay), 1
2
4
5
Circuitry has
®
Description
System armed
System armed with
Bypass Notification
System disarmed
System disarmed with
Tamper Alert
System disarmed NPC
active
®
27