Programming Mode - Cornelius FlavorFusion Installation Manual

Flavorfusion with cold carbonation
Hide thumbs Also See for FlavorFusion:
Table of Contents

Advertisement

P
M
ROGRAMMING
The programming mode is exactly the same for both brand and bonus keypads.
To enter the programming mode, press and hold the two program buttons at the top of the keypad for approximately
4 seconds. All keypad LEDs will flash off for approximately 1 second to indicate the start of the programming mode.
To exit programming mode, press and hold the two program buttons for approximately 4 seconds. All keypad LEDs
will flash off for approximately 1 second, resuming normal operation mode.
Programming Mode Flashing Sequences
Once in programming mode, each dispense button LED flashes in a sequence cycle according to one (1) of six (6)
dispense types. For Brand Keypads, only dispense types 1 and 2 are used. For Bonus Flavor Keypads, dispense
types 3 through 6 are used. The six (6) dispense types are described below, and shown in a timing diagram:
Dispense Type 1, Carbonated water dispense: Solid LED
Dispense Type 2, Non-carbonated dispense: Flashing LED 1.5 seconds ON, 1.5 seconds OFF
Dispense Type 3, 1-second flavor shot: LED flashes once for ¼ second, followed by 3 seconds OFF
Dispense Type 4, 2-second flavor shot: LED flashes twice for ¼ second ON, ½ second OFF, followed
by 3 seconds OFF
Dispense Type 5, 3-second flavor shot: LED flashes three (3) times for ¼ second ON, ½ second
OFF, followed by 3 seconds OFF
Dispense Type 6, 4-second flavor shot: LED flashes four (4) times for ¼ second ON, ½ second OFF,
followed by 3 seconds OFF