Operation - MULTIQUIP GAC6HRS Operation And Parts Manual

Honda gx340rt2edn2/gx340rt2ede2 gasoline engines
Table of Contents

Advertisement

W
G
120VAC
X
L5-30R
120V
120
V
Figure 23. 120V Twist-Lock/GFCI Receptacles
13. Place the full power switch (Figure 24) in the 240/120V
position (down).
240/120V
Figure 24. Full Power Switch
240/120V Position (Down)
14. Read voltmeter on front panel of generator (Figure 25)
and verify that 240 VAC is displayed. Using an external
voltmeter as shown in Figure 25, verify that 240 VAC is
present at the 120/240V, L14-30R twist-lock receptacle.
PAGE 26 — GAC6HR/HRS 60 HZ GENERATOR• OPERATION AND PARTS MANUAL — REV. #1 (12/13/17)
GFCI
120 VAC
OFF
V~
V
300 mV
A~
A
V
COM
DOWN
120VAC
L14-30R
X
L14-30R
120VAC
W
G
W
120VAC
Y
240
V
Figure 25. 120/240V L14-30R Receptacle
NOTICE
When using a combination of dual receptacles, total
load should not exceed the rated capacity of the
generator.
15. Connecting of loads (power tools, lighting etc.) to the
generator receptacles can now be done.

OPERATION

240VAC
X
G
Y
240 VAC
OFF
V~
V
300 mV
A~
A
V
COM

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gac6hr

Table of Contents