Components (Generator) - MULTIQUIP GAC6HRS Operation And Parts Manual

Honda gx340rt2edn2/gx340rt2ede2 gasoline engines
Table of Contents

Advertisement

2
1
1. GFCI Duplex Receptacles – NEMA 5-20R, GFCI
receptacle will provide 120V@ 20 amps.
2. Main Breaker – This 2-pole, 20 amp circuit breaker
protects the generator from short circuiting or
overloading. When starting the generator always have
the circuit breaker placed in the "OFF" position.
3. Hour Meter – Indicates the number hours the generator
has been in use.
4. AC-Voltmeter – This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition, the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools turn the generator OFF and consult your
authorized Multiquip service dealer.
5. Idle Control Switch – The generator is provided with
an automatic idle control device for noise suppression
and reduced fuel consumption.
The automatic idle control automatically engages under
a no-load condition. With the automatic idle control
switched "ON", the engine revolutions will automatically
drop to about 2600 rpm (low-speed operation) within
3 seconds after the load stops. When the operation is
resumed, the engine speed is automatically increased
to about 3600 rpm (high-speed operation) as soon as
the load is connected.
GAC6HR/HRS 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (12/13/17) — PAGE 19
3
4 5
GAC-6HR
V
V
120
120
120
120
MARCHE
ON
MARCHE
ON
AC VOLTMETER
VOLTOMETRE CA
ARRET
OFF
ARRET
OFF
120V
120V
IDLE
OPERATION
MAIN AC CIRCUIT BREAKER
CONTROL
SWITCH
CONTROL
INTERRUPTEUR
DISJONCTEUR PRINCIPALE DE COURANT CA
DE RALENTI
DU OPERARION
QUARTZ
QUARTZ
240/120V
240/120V
FULL POWER
SWITCH
120V
20A
120V
20A
HOUR METER
120V
30A
120/240V
20A
INTERRUPTEUR
COMPTEUR
PLEINE
D' HEURE
PUISSANCE
GR
NEUTRAL BONDED TO FRAME.
PRISE DE
TOTAL LOAD WITHIN
5kW
TERRE
NEUTRE MIS A LA MASSE A
CHARGE TOTALE MAX. 5kW
LA CARCASSE DU MOTEUR.
Figure 4. Generator Components

COMPONENTS (GENERATOR)

6
GAC-6HRS
MAIN AC CIRCUIT BREAKER
DISJONCTEUR PRINCIPALE DE COURANT CA
QUARTZ
QUARTZ
HOUR METER
120V
20A
120V
20A
COMPTEUR
D' HEURE
NEUTRAL BONDED TO FRAME.
TOTAL LOAD WITHIN
NEUTRE MIS A LA MASSE A
CHARGE TOTALE MAX. 5kW
LA CARCASSE DU MOTEUR.
13
6. Operation Switch –Place switch in the "ON" position
(up) for normal operation. To turn-off the generator,
place the operation switch in the "OFF" position (down).
7. Lifting Bail Eye – Attach a rope or chain to this lifting
eye when lifting of the generator is required. Never
stand underneath the generator while it is being lifted.
Place lifting eye in down position when not in use.
8. Start Switch – Press this pushbutton switch to start
the generator (GAC6HRS only).
9. Ground – This ground connection point should be
connected to a good earth ground ground rod).
10. 120/240V Output Receptacle – NEMA L14-30R twist-
lock receptacle will provide 240V, 60 Hz @ 20.8 amps,
or 120V@ 41.6 amps (X2) 60 Hz. Depending on the
position of the full power switch.
11. 120V Output Receptacle – NEMA L5-30R twist-lock
receptacle will provide 120V, 30 amps, 60 Hz.
12. Battery – This unit is equipped with a 12 VDC
battery. Replace with only recommended type battery
(GAC6HRS only).
13. Charcoal Canister – A container filled with activated
charcoal that traps gasoline vapors emitted by the
fuel system.
7
V
V
120
120
120
120
MARCHE
ON
MARCHE
ON
AC VOLTMETER
VOLTOMETRE CA
ARRET
ARRET
OFF
OFF
120V
120V
IDLE
OPERATION
CONTROL
SWITCH
CONTROL
INTERRUPTEUR
8
DE RALENTI
DU OPERARION
240/120V
240/120V
FULL POWER
SWITCH
START
120V
30A
120/240V
20A
INTERRUPTEUR
BUTTON
PLEINE
BOUTON DE
PUISSANCE
DEMARRAGE
GR
5kW
PRISE DE
9
TERRE
10
11
12