Configuring MDA Parameters
MDA information must be must be configured before ports can be configured.
After the IOM is configured, use the following CLI commands to provision the MDA(s). A
maximum of two MDAs can be configured on an IOM.
Step 1
Step 2
Step 3
Step 4
To provision an additional MDA, continue the configuration process with Step 5:
Step 5
Step 6
Step 7
Step 8
Example
The following example displays card slot, card type, MDA slot, and MDA type command usage:
ALA-7>config# card 1
ALA-7>config>card# card-type iom-20g
ALA-7>config>card# mda 1
ALA-7>config>card>mda# mda-type m60-10/100eth-tx
ALA-7>config>card>mda# no shutdown
ALA-7>config>card>mda# exit
ALA-7>config>card# mda 2
ALA-7>config>card>mda# mda-type m10-1gb-sfp
ALA-7>config>card>mda# no shutdown
ALA-7>config>card>mda# exit
7450 ESS-7
Command
mda mda-slot
mda-type mda-type
no shutdown
exit
mda mda-slot
mda-type mda-type
no shutdown
exit
Installing IOMs and MDAs
Example
mda 1
mda-type m60-10/100eth-tx
no shutdown
exit
mda 2
mda-type m10-1gb-sfp
no shutdown
exit
Page 97