Run The Barrel Motor - Cornelius VIPER Service Manual

3 flavor low overrun
Hide thumbs Also See for VIPER:
Table of Contents

Advertisement

Viper Low overrun Service Manual

Run the Barrel Motor

Step
1
2
3
4
NOTE: When RUN button is pressed, it changes to a STOP button.
Rinsing a Barrel
When rinsing a barrel, the Barrel Maintenance menu cannot be used. The procedure must be done manually, as
described in Table 24.
Step
1
2
3
4
5
6
7
Manual Diagnostic Menu
The Manual Diagnostic menu, shown in Figure 22, is used for troubleshooting and testing the system on a compo-
nent basis. It allows the service technician to turn individual components of the system on and off for troubleshoot-
ing purposes. Pressing the BACK button returns the display to the Main menu and turns off all the active loads.
This screen should only be used by qualified technicians to troubleshoot the system.
Publication Number: 621360241LOEWSE
Action
From the Setup menu (Figure 20), open the Barrel
Run a barrel
Maintenance menu, shown in Figure 21.
Use the Up and Down arrows to highlight the desired
Select the barrel
barrel
Press the SPIN button at the bottom of the display to
Select Run function
start the motor in the highlighted barrel
Press the STOP button at the bottom of the display to
Stop the procedure
stop the motor. Press the BACK button to return to the
Select menu.
Action
If the barrel has liquid in it, use the Purge procedure in
Empty a barrel
Table 21 to empty the barrel.
Rinse a barrel
Go to the Barrel Status menu (Figure 6).
Use the Up and Down arrows to highlight the desired
Select the barrel
barrel
Press the OFF button at the bottom of the display to
Turn off the barrel
turn off the barrel.
Press the manual bypass on the water solenoid and
fill the barrel with plain water. Use the relief valve on
Override Water Solenoid
the faceplate of the barrel to relieve pressure and
completely fill the barrel.
Run the barrel motor
Use the procedure in Table 23 to rinse the barrel.
Repeat the Purge procedure in Table 21 to empty the
Complete the procedure
barrel.
Table 23.
Procedure
Table 24.
Procedure
- 26 -